<strong>Reactive</strong> <strong>Power</strong> <strong>Controller</strong>Diagr.: Expanded programming, part 2 of 2Averaging time for mean value cos(phi)Averaging time for reactive powerVArhProgProgVArsVentilator control, upper temperaturelimitFan control, lower temperature limitVentilator control, outputProgProgOvertemperature disconnection, upperlimitProgProgOvertemperature disconnection, lowerlimitProgOvertemperature disconnection, pausetimesProgDisplay in manual modePasswordProgProgContrast6ProgReset programmingProgConnection configurationProgSoftware ReleaseSerial number, part 1Serial number, part 2AddressProgProtocolProgBaud rateProgPage 52= Key 1 = Key 2 = Key 3
<strong>Reactive</strong> <strong>Power</strong> <strong>Controller</strong>Configuration dataDescriptionSetting rangeManufacturer's presettingStandard programmingTarget-cos(phi1) 0.80cap. .. 1.00 .. 0.80ind. 0.96indTarget-cos(phi2) 0.80cap. .. 1.00 .. 0.80ind. 0.90indCT ratio 1 .. 9999 10Learning of configuration oN, oFF oFFStage power of 1. stage 0var .. 9999kvar 10kvarStage ratio 0 .. 9 1:1:1:1Switching outputs 1 .. 12 all stagesFix stages 0 .. 3 0 = no fix stagesDischarge time 0 .. 1200 seconds 60 Sec.Disconnection pause for relay stages 0 .. 1200 seconds 40 Sec.Switching frequency for semic. stages 0.1, 0.2, 0.5, 1.0, 10.0, 50.0Hz 1) 1.0 Hz<strong>Power</strong> station service on, oFF oFFStage power, 1. - 12. capacitor stages 0var .. 9999kvar 10kvarChoke degree 0 .. 15% 0 %VT ratioNumber 1 (Primary) 1 .. 9.999k 1Number 2 (Secondary) 1, 10, 100, 110, 200, 230, 400 1Harmonic table number 0 .. 10 0Alarm callsLow voltage on/1, oFF oFFOvervoltage on/2, oFF oFFCurrent too low on/3, oFF oFFCurrent too high on/4, oFF oFFInsufficient capacitor power on/5, oFF oFFSupply of real work on/6, oFF oFFHarmonic limits exceeded on/7, oFF oFFOvertemperature on/8, oFF oFF 2)Averaging time of reactive power 0.1, 0.5, 1.0, 5.0, 10.0, 30.0, 60.0Sek. 60.00 Sec.Averaging time for mean value cos(phi) 0.25, 0.50, 1.00, 2.00, 12.00, 24.00h 24.00 hVentilator controlUpper temperature limit 0 .. 99°C 0°CLower temperature limit 0 .. 98°C 0°COutput number 0 .. 13 (13 = alarm output) 0 = no ventilator controlOvertemperature disconnectionUpper limit 0 .. 99°C 55°CLower limit 0 .. 98°C 50°CPause time 0 .. 1200 seconds 600 secondsIndication in manual mode CoS = cos(phi), CAr = react. power CAr = react. powerPassword 0 .. 9999 0000 = no passwordContrast 1 .. 12 6Reset programmingConnection configuration 0° .. 359° 000°Software Release x.xxx actual versionSerial number part 1 xxxx depending on deviceSerial number part 2 xxxx depending on deviceSerial interfaceDevice address 0 .. 126 001Protocol 0 .. 1 0Baud rateModbus RTU 0=9.6, 1=19.2, 2=38.4, 3=57.6, 4=115.2 0 ( = 9.6kbps)Profibus DP V0 Automatical adaption up to 1.5Mbps at maximum1) For inner temperatures of over 70°C an alarm is always raised.2) If a switching frequency of 50Hz is programmed for the transistor outputs, the serial interface does not work!Expanded programming= Key 1 = Key 2 = Key 3Page 53