<strong>Reactive</strong> <strong>Power</strong> <strong>Controller</strong>Alarm outputIn undisturbed ope-ration,the alarm relay at-1 ErrorVtracts, and the contact%of the alarm output isProgclosed. In case of a disturbance,the alarm relay releases and the contact isopened. Various events can be assigned to the alarmoutput via or-conjunctions. One alarm number, one alarmdelay and one alarm duration are assigned to each event.The alarm call can be activated or deactivated for eachevent."on"/number = Alarm call is activated."oFF" = Alarm call is deactivated.The following events can be assigned to the alarm output:AlarmnumberEvent Condition1 Lower voltage oFF/number2 Overvoltage oFF/number3 Underscoring of meas.current oFF/number4 Exceeding of meas. current oFF/number5 Insufficient capacitor output off/on6 Supply of real power off/on7 Harmonic thresholds oFF/number8 Overtemperature oFF/numberExample: Programming compensation powerLeaf to the first alarm in the expanded programmingwith key 3. Please leaf to compensation power (5) withkey 2 and confirm with key 1.Alarm callIf one or more alarms occur, Prophi changes to an alarmindication. In the alarm indication, the errors are shownby their number. In the following example, the errors"lower voltage" and "compensation power" occurred.The time and dimension of the error is not saved.Low voltageCompensation power1 5 ErrorGive a receipt for alarmsIf you confirm the alarm message with key 3, you reachthe last measured value indication. The error symbol"Error" remains within the measured value indicationsuntil the errors are not valid anymore.Example: Alarm messageError symbolcosϕind2 3 ErrorIf other error messages appear after the confirmation ofan error message, the alarm indication appears againwith new error messages. Older errors, which are notvalid anymore, are flashing.ϕ15 ErrorVArProgWith key 3 the alarm "compensation power" is activated(on), with key 2 the alarm "compensation power"is deactivated (oFF).Pressing key 1 you leave the programming mode andwith key 3 you can continue leafing through the expandedprogramming.Page 32= Key 1 = Key 2 = Key 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!