INSTALLATION AND OPERATION<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 1August 2013


Contents 2Included 4General 5Mounting the <strong>USA</strong> 7Electrical Connection 12Commissioning 14Setting the <strong>USA</strong> 15Operation 19Function Test and Maintenance 21Fuses 23Standards 24Technical Data 25<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 2August 2013


The installation of the <strong>USA</strong> must follow the following statements bya registered trained specialist, since safety and operability of thesystem depend on proper organization. The applicable professionalregulations the craft and the building regulations must be observed.Please read these instructions carefully before beginninginstallation. For damages caused by failure to observe theseinstallation instructions, accounting for all warranty and warrantyclaims.Improperly executed work can lead to injuries and damage toproperty!Proper operation of the <strong>USA</strong> equipped with ventilation andcombustion is guaranteed only if the combustion air supply to theappliance and the operational and fire-safe removal of the exhaustgases is ensured and that of the company that says Fireplacerecommended fuels.Ensure that the electrical supply is isolated before any workis carried out on the <strong>USA</strong>.National and local codes must be met.Further, the device attached instructions must be observed.Subject to technical changes.Transport damage, please immediately notify the supplier!Please keep instructions!<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 3August 2013


INCLUDEDTo build a functional negative pressure safety shutdown thefollowing components are required:• Under pressure safety switch <strong>USA</strong> (Art.Nr.: 11600.1)• Exhaust gas sensor connection for <strong>USA</strong> (Art.Nr.: E007036),consisting of:• Temperature sensor PT1000• Perforated band• Flush-mounted box (Art.Nr.: 900001)• Vacuum hose (Pressure gauge line)* (Art.Nr.: 11602)• Sensor cable * (Art.Nr.: 12120 - 12124)• Cable support spring• Adapter• Insulation• Lug clamps• Please order length (max. 10m) according to the structuralconditions!Check your delivery is complete.Note material composition: pressure gauge line and sensor wiremust be run in conduit (16mm)!The software for configuration of U.S. and the full text of DIBT -Admission can be downloaded from the Craftsmen area ofwww.brunner.de.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 4August 2013


<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 5August 2013


The vacuum circuit breaker safety (<strong>USA</strong>) is used in rooms where aroom sealed combustion and ventilation system can be operatedsimultaneously and shutdown due to an external fault (eg responseto a vacuum monitoring is required to the appliance).The <strong>USA</strong> is used to monitor a minimum pressure differencebetween the room where the fireplace and the exhaust pipe to ensureadequate combustion air supply and the safe transfer of theflue gases. Falls below a minimum pressure difference in theventilation system (at least the exhaust air fan) will switch the fanoff.The <strong>USA</strong> can work with all air-ventilated manually fed furnacesaccording to DIN EN 12815, DIN EN 13229 and DIN EN 13240.The design of the stove installation is done without consideration ofthe ventilation system of the Installation room. This ensures thatthe air supply to the combustion process by switching off theventilation is guaranteed by <strong>USA</strong>.For systems that are monitored by the <strong>USA</strong>, multiple usage of thechimney is not allowed!Note the maximum temperature stresses (see technical details).This manual, especially the entries in the chapter 'Setting the <strong>USA</strong>'are from operators preserved and passed on request to the BSM<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 6August 2013


MOUNTING OF THE <strong>USA</strong>Important note!The <strong>USA</strong> should be mounted inthe same room as the applianceto be monitored. Location of thefireplace means the place fromwhich the fireplace gets the airrequired for combustion.The pressure gauge linebetween electronics of the <strong>USA</strong>and heating and exhaust pipemust not be kinked or laid with ahanging loop. The length of thepressure measuring line mustnot exceed 10 m. The function ofthe <strong>USA</strong> would no longer beguaranteed.Observe installation of the <strong>USA</strong>in the wall box and ensure thatthe silicone hose is not kinked orcrushed for connecting thepressure gauge line. Thefunction of the <strong>USA</strong> would nolonger be guaranteed.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 7August 2013


Do not blow into the port ofthe pressure measuringline!The pressure compensationopening can be closed.Do not paint over!Do not wall paper over!Before plastering, the flushmountingbox of the <strong>USA</strong> mustbe removed from the wall box!In order to avoid subsequentdamage to the electronics, theinstallation of the <strong>USA</strong> must becarefully planned and executed.Figure 3: Pressure equalizationport (X) on top of the <strong>USA</strong>To do this, note the followingpoints:Tip: Set the flush box withscrewed plastic lid. This willensure distortion-freeinstallation.- Avoid any contact with theelectronic components, as staticelectricity can damage thesecomponents.- Construction moisture damageelectronic components.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 8August 2013


• If possible do not install the <strong>USA</strong> in an external wall, to avoiddew point corrosion to the electronics.• Do not install the <strong>USA</strong> in the heated tile cladding.• The mounting shall be such that does not exceed +50 ° C and+10 ° C are not exceeded and the device is not exposed to directheat radiation.• The degree of protection IP 40 is ensured.StructureThe electronics of the <strong>USA</strong> should (observe permissible ambienttemperatures!) be near the hearth place.An ideal position is slightly above the exhaust sensor port, becauseyou can then ensures that any condensate in the pressure gaugeline runs back to the exhaust gas sensor connection (see alsoFigure: Laying the pressure gauge line).The exhaust gas sensor circuit is to be mounted at a locationwhere the ambient temperature of 180 ° C and the coretemperature of the flue gas does not exceed 500 ° C.This is usually guaranteed in the flue gas at a distance between 70cm and 150 cm from the hearth. Of the pressure measuring pointof the fireplace must not exceed 150 cm. They can be connectedto pipes with diameters from 150 mm to 250 mm.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 9August 2013


Drill two 7mm holes in the fluepipe 20mm apart.Install the clamp bracket (6)around the flue. Ensure that theholes in the clamp line up withthe drilled holes.Insert the temperature sensor(2) and the connecting pipe forthe pressure measuring line(4).The temperature sensor shouldbe inserted so that the min. 75mm is in the exhaust stream.Now put the steel strip (7) intothe slot of the first bolt andsecure it with about two turns ofthe screw. Tighten the nut.Figure 4: Exhaust gas sensor connectionThe cut the steel strip so that about 3-5 cm is on left.Now, the exhaust gas sensor connection can be secured bytightening the screw.Lead the sensor cable and the pressure gauge line in a conduit to<strong>USA</strong> and connect.Ensure that the pressure gauge line does not kink or crush.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 10August 2013


Connect the pressure gauge lineto the exhaust sensor connectionwith a ‘lug clamp’. Installation isas shown on the image.The pressure measuring line isconnected to the adapter in thedelivery of the silicone tube ofthe <strong>USA</strong>. The pressure gaugeline with an 'lug clamp'.Note that the ’lug clamp’ (5)cannot be opened withoutdamage. The lug clamps are notre-usable.5 Mounting the lug clamps6 AdaptorThe Cable support spring (3)must be pushed over thepressure gauge line at the pointof highest risk of buckling(= bending radius).7 Cable support spring<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 11August 2013


ELECTRICAL CONNECTIONThe connection of power cable,air / fan and temperature sensorsare shown in the followingdiagrams.To isolate the <strong>USA</strong> for servicingor maintenance, we recommendthe installation of an emergencyswitch or a separate fuse.When installing an emergencyswitch, ensure that power isactually a separation. (Notestarting current) for ventilationsystems, fume hoods, kitchenfans, etc. with a powerconsumption of less than 2A isthe electrical connection asshown in the picture.8 Connect a ventilation system with anominal current of 2a<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 12August 2013


Ventilation systems, fume hoods, kitchen fans, etc. with a powerconsumption of more than 2A must not be connected directly to the<strong>USA</strong>.There must be a power contactor installed.This contactor is part of thesafety device and must meet therequirements of EN 50165-1 (ie60947 and contactors must bedesigned by a mechanical life3x106 switching cycles haveEN).Welding of the contacts to protectagainst a backup is required,which reduces the maximumpermissible switching current ofthe contactor to the 0.6 times. Anexample of such a circuit isshown in the picture.Relay is open. When stove is in operationand under pressure to low air contact ismadeSchematic diagram show connection formultiple fans.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 13August 2013


COMMISSIONINGTurn the <strong>USA</strong> on, subsequently,the <strong>USA</strong> performs a self-test(approx. 1 min).During this time, the output willbe disabled, ie the ventilationsystem is off.This condition is indicated by theillumination of the green and thered LED.The self-test is repeated oncedaily to the time ofcommissioning.During the self-adaptation of theswitching, output is disabled. Inaddition, the measurement cell<strong>USA</strong> recalibrated to ensure aprecise measurement every 15minutes.This self-test recognizes two soft clack noise. When the red LED isoff, the <strong>USA</strong> is ready.The measurement of temperature and reduced pressure isperformed automatically.It needs no further action.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 14August 2013


SETTING THE <strong>USA</strong>The <strong>USA</strong> can be a PC with RS232 - Setting the interface andthe parameters of the localconditions.The parameters can bedownloaded on our website athttp://www.brunner.de/de/Service/Produktdownloadsand installed on a PC:To unpack the zip file and run theexe.Note: First, always make the cable connection, then launch theprogram.To connect the <strong>USA</strong> to a PC serial cable is required.To connect to a USB port on the PC USB-to-serial converter is alsorequired.It is important to ensure that only the COM ports 1 to 4 are available.Warning: Not everyone fits the converter used PC! We use so far:http://de.farnell.com/ftdi/us232r-100/kabel-usb-rs232-seriellkonverter/dp/1329310?Ntt=1329310without abnormalities.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 15August 2013


Error codes:ErrorCodeChanging the parameters of the <strong>USA</strong> may only be made bytrained personnel and must be recorded in the table below.The operator should be noted that the settings cannot bechanged.MeaningErrorCodeMeaning0001 Frequency error 0002 Supply voltage0004 Oscillator voltage 0008 Offset voltage0010 Relay error 0020 EEPROM data0040 Invalid state 0080 Invalid temperaturesetting0100 Compressive stress hasreached limit0200 Invalid parametersetting0400 Program code error 0800 Error when checkingthe data area1000 Error at 5v supply 2000 Specify minimumtime4000 Error Watchdog test 8000 Error hardware<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 16August 2013


Status indicators:StatusdisplayMeaningStatusdisplayMeaning0 Switch 1 TW - Delay2 Temperature monitoring 3 Pressure monitoring4 Delay 5 TA - Delay6 Troubleshooting 7 Troubleshooting confirmedwith key8 - 13 ZeroingSetting values and their meanings:Description Abbr. Range Factorysetting )*Pressure limit dp_soll 4 Pa - 20 Pa 4 PaUp Time Tw 1 min - 30 min 1 minDelay for switching off whilebelow the boundaryWaiting time betweenshutdown and re-checkingTemperature for activation ofthe pressure monitoringsystemTv 1 sec - 30 sec 20 secTa 1 min - 30 min 15 minTemperature 20°C - 100°C 50 °C) * Value in delivery stateDuring commissioning, the set values are to be checked and in thefollowing table entered. The <strong>USA</strong> must be tested with the enteredvalues and put into operation are. With these changes are to taketo the table.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 17August 2013


The settings must be made depending on the local conditions andconditions ( exhaust emissions of 30 ppm CO may not be exceeded).Settings for operation:The settings listed above have been checked and tested thefunction of the <strong>USA</strong>.Name ……………………………………………………………………..Date ……………………………………………………………………….Signature …………………………………………………………………<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 18August 2013


OPERATIONThe <strong>USA</strong> offers the possibility of excluding the automaticmeasuring process after a failure to start manually resolved nofurther possibilities of use.The button for starting the measurement is located behind theglass sheet below the fault indication and is accessible only afterremoving the glass plate. Slide the glass plate up and out.The light emitting diodes (LED) on the front panel of the <strong>USA</strong>provide information on the status of the device:Green LED is offGreen LED is onGreen LED flashesRed LED is offRed LED is on<strong>USA</strong> is off.<strong>USA</strong> is working.Output for ventilation system is inoperation (there is no monitoring becausethe measured temperature is less than50 ° C *), ie no combustion is taking place).<strong>USA</strong> is active.Combustion is detected (temperaturegreater than 50 ° C *)). The pressure ratiosbetween indoor and heater arecontinuously tested.No fault.<strong>USA</strong> has triggered(Ventilation system was switched off,the differential pressure is too low)Note: If the <strong>USA</strong> has triggered the ventilation system is turnedon again at the earliest after 15 minutes *) and only when thereis sufficient pressure differential.<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 19August 2013


Red LED FlashesSystem fault• Damage to the <strong>USA</strong>• The temperature sensor is not connected or connected incorrectly.• A blockage in the chimney during the burning phase, anegative pressure greater than 8.5 Pa.• The supply voltage of the <strong>USA</strong> is below 200 volts.By pressing the start button for more than 5 seconds ordisconnection from power supply and troubleshooting the errorcause is the <strong>USA</strong> Immediately ready for use*) Value in delivery state<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 20August 2013


FUNCTION TEST AND MAINTENANCEWhen the <strong>USA</strong> responded:<strong>USA</strong> constantly monitors the temperature of the flue pipe, theoperating status is indicated by the green LED. If the temperaturerises above 50 ° C (default), a burn is detected, the green LEDstarts to flash, from here the vacuum of the chimney is monitored.In order to ensure a safe exit of flue gases a comparison betweenthe room and the flue must be made, there must be a vacuum ofat least 4 Pascal.An exhaust hood or a controlled living space ventilation canproduce much higher vacuum, the subsequent flow of air isprevented by the modern, tight construction. To prevent backflow ofexhaust gas into the room, <strong>USA</strong> must stop the fan, in this case:the red LED will light and the ventilation system will be switchedoff.Function test:To test the function of the <strong>USA</strong>, connect the power and the vacuumsensor (green LED illuminated).The temperature sensor must reach approximately 50°C (greenLED flashes) (value in delivery state).Hold the vacuum hose into the room (do not connect to thechimney and not blow into it). Within about 30 seconds, the <strong>USA</strong>should shutdown (red LED lights).<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 21August 2013


The vacuum circuit breaker safety (<strong>USA</strong>) is in compliance with thebasic maintenance measures in accordance with DIN 31 051 inconjunction. DIN EN 13 306 to maintain operation by a specialist.The home owner must test the <strong>USA</strong> at least once a month.Turn off the power to the <strong>USA</strong> ( the ventilation system / hood willstop working ), when the power is turned on again the <strong>USA</strong> willreturn to normal start up.Check the pressure compensation opening / s for blockage andclean if necessary.Check the screws of the mounting of the sensor and retighten ifnecessary.Check the pressure gauge line for blockage and clean if necessary.Check the correct position of the clamp and seal the flue andcorrect if necessary.Contaminants in the flue delay the response time of thetemperature sensor!<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 22August 2013


FUSESThe <strong>USA</strong> has three miniature fuses. These are located on theboard.Subminiature Fuse X (T2A)Product No.: 025552 x miniature fuse-Y (T160mA),No.:02551<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 23August 2013


STANDARDSDIN VDE 0116Electrical equipment for furnacesDIN EN 13240CO content at the boiler roomEN 60730-1:2002-01 Equipment and labeling must complywith these requirementsEN 60730-1 Appendix H Software must use their actionEN 50165 Section 19.101 Must control their disorders withstand<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 24August 2013


TECHNICAL DATAThe <strong>USA</strong> has been tested by TÜV South Germany GmbHGeneral building approval by DIBt; approval number Z-85.1-8.Test Report C 1207-00/04 vom 31.03.2004Dimensions 170 x 170 x 60 (b x h x t)ProtectionOperating VoltagePressure Sensor RangeFuseFuse Switch OutputIP20 / DIN 40050 CE230 V +10% -15% / 50Hz / 3VA-8.5 Pa - 50 PaT 160 mAT2AAmbient Temperature 10 °C - 50 °CTemperature SensorMeasuring Range PT100 -40 to 600 °CPT1000 exact degree of DIN EN60751Maximum Temperature Loads PT1000 Metal Braid –50 to 350°CMeasuring Hose 260°CTemperature Resistance Table for PT1000<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 25August 2013


<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 26August 2013


<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 27August 2013


<strong>Robeys</strong> <strong>Ltd</strong>Goods Road Industrial EstateBelperDerbyshireDE56 1UUTel: 01773 820940Fax: 01773 820477Email: info@robeys.co.uk<strong>Brunner</strong> <strong>USA</strong> Installation & Operation Manual 28August 2013

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!