13.07.2015 Views

Tab 16.book - Piti Group

Tab 16.book - Piti Group

Tab 16.book - Piti Group

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.SquareD.comFor the most up-to-date informationLA9F980LA9D09981Suppressor BlocksAccessoriesTeSys F-Line ContactorsOperating limit: up to 220 V, 50/60 Hz coilsDescription For Use Catalog Number PriceWith coils LX1FF, FG, FH, F115, F185, F265, F330 LA9F980 $21.80Suppressor block(clip-on mounting to coil)With coilsLX1FJ, FK, FL, FX, F400, F500, F630, F780LX9FF, FG, FH, F115, F185, F265, F330LA9D09980 20.70Mounting bracket (for 35 mm DIN rail or panel mounting) for suppressor block LA9D09981 5.50Lugs—3-PoleContactorType LC1Lug KitCatalog NumberCable Size AL/CUF115 DZ2FF6 14 to 2/0 $ 39.30F150, F185 DZ2FG6 6 to 3/0 65.00F265, F330 DZ2FH6 6 to 300 MCM 65.00F400 DZ2FJ6 4 to 500 MCM 65.00F500 DZ2FK6 2 X 2 to 600 MCM 131.00F630, F800 DZ2FL6 3 X 2 to 600 MCM 164.00F780 DZ2FX6 4 X 1/0 to 750 MCM 164.00Lugs for LC1F must be ordered separately. Each kit consists of six (6) lugs. Mounting hardware (screws, washers, nuts) are provided with the contactor,not the lugs.PriceLugs—2 and 4-PoleContactorLug KitQty. RequiredAL/CUType LC1Catalog Number 2-Pole 4-PoleCable SizePriceF115 DZ2FF1 4 8 14 to 2/0 $ 6.50F150, F185 DZ2FG1 4 8 6 to 3/0 11.00F265, F330 DZ2FH1 4 8 6 to 300 MCM 11.00F400 DZ2FJ1 4 8 4 to 500 MCM 11.00F500 DZ2FK1 4 8 2 X 2 to 600 MCM 21.80F630 DZ2FLa a N/A 3 X 2 to 600 MCM aF780 DZ2FX1 4 8 4 X 1/0 to 750 MCM 28.30Lugs for LC1F contactors and overload relays must be ordered separately. Each kit consists of one (1) lug. Mounting hardware (screws, washers, nuts)are provided with the contactors, not the lugs.a For 2-pole F630 contactors, order 2 DZ2FL1 (L1 and T2), and 2 DZ2FL3 (L2 and T1). For 4-pole F6304, order 2 DZ2FL1 (L1 and T4), 4 DZ2FL2(L2, T2, L3, T3) and 2 DZ2FL3 (L4 and T1). All three are priced at $27.30 each.Power Terminal Protection ShroudsThese clear plastic protective shrouds are an effective means to meet international touch-safe requirements forpower terminals. They are designed to be used with power cables that have been bolted to the terminal.LA9F70tNote: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits.For Use With 2-, 3-, And 4-pole Contactors Number of Shrouds Per Set Set Catalog Number PriceLC1F115 6 LA9F701 $ 42.40LC1F150, F185CR1F150, F1856 LA9F702 61.00LC1F225, F265, F330, F400 and F4002, F500 and F5002CR1F265, F400 and F5006 LA9F703 82.00LC1F630, F6302 and F800CR1F6306 LA9F704 93.00LC1F1154 8 LA9F706 58.00LC1F1504 and F1854 8 LA9F707 80.00LC1F2254, F2654, F3304, F4004, F5004 8 LA9F708 111.00LC1F6304 8 LA9F709 120.00Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-28–16-29For additional information, reference Catalog #8502CT9901R5/03.IEC STYLE CONTACTORSAND STARTERS16© 2003 Schneider ElectricAll Rights Reserved9/8/039/8/03I12DiscountSchedule16-11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!