AccessoriesTeSys Manual Starter and Protectorwww.SquareD.comFor the most up-to-date informationGVAU116GVAE11Voltage TripsOnly one trip or fault signaling contact can be installed per GV2/GV3 device.Description Characteristics Voltage Frequency Catalog Numbera PriceVoltage trips GV2Undervoltage orShunt trip(external mount,1 block right side only)24 V50 Hz GVAt02560 Hz GVAt02648 V50 Hz60 HzGVAt055GVAt056100–110 V 50/60 Hz GVAt107110–115 V50 Hz60 HzGVAt115GVAt116120–127 V 50 Hz GVAt125127 V 60 Hz GVAt115200 V 50 Hz GVAt207200–220 V 60 Hz GVAt207220–240 V50 Hz GVAt22560 Hz GVAt226$54.00380–400 V50 Hz60 HzGVAt385GVAt386415–440 V 50 Hz GVAt415415 V 60 Hz GVAt416440 V 60 Hz GVAt385480 V 60 Hz GVAt415500 V600 V50 Hz60 HzGVAt505110–127 V 50 Hz120–127 V 60 HzGV3B11Undervoltage trip(internal mount)220–240 V240–277 V50 Hz60 HzGV3B22380–415 V 50 HzVoltage trips f480 V 60 HzGV3B38GV3110–127 V 50 Hz120–127 V 60 HzGV3D1154.00Shunt trip(internal mount)220–240 V240–277 V50 Hz60 HzGV3D22380–415 V480 V50 Hz60 HzGV3D38a To order an under voltage trip: replace the bullet (t) with a U, example: GVAU025. To order a shunt trip: replace the bullet (t) with an S,example: GVAS025.IEC STYLE CONTACTORSAND STARTERS16GVAD0101GVAN11Auxiliary Contact BlocksDescriptionInstantaneous auxiliary contactsGV2Fault signaling contact +instantaneous auxiliary contactGV2Short circuit signaling contactGV2Instantaneous auxiliary contactGV3Fault signaling contactGV3MountingLocationMax.No. ofBlocksFrontbg 1Left Hand Side 2Left Hand Sided 1b Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P and GV2L.c Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.d The GVAD is always mounted next to the starter.e For spring terminals add 3 to the catalog number. Example: GVAE113f One trip or one fault signaling can be fitted per GV3.g Cannot be used with GV2GH7 insulator.h From the loss of voltage at the trip terminals to the opening of the starter contacts.Contact TypeSold inlots ofCatalogNumberPriceN.O. or N.C.c 1 GVAE1 $14.50N.O. + N.C. 10 GVAE11e 23.80N.O. + N.O. 1 GVAE20e 23.80N.O. + N.C. 1 GVAN11e 23.80N.O. + N.O. 1 GVAN20e 23.80N.O. (fault) + N.O. 1 GVAD1010 36.20N.O. (fault) + N.C. 1 GVAD1001 36.20N.C. (fault) + N.O. 1 GVAD0110 36.20N.C. (fault) + N.C. 1 GVAD0101 36.20Left Hand Side 1 SPDT 1 GVAM11 23.80Side mount(1 block per device)Internal mount f(1 block per device)Voltage Trips–Technical Data (GV2AU, GV2AS, GV3B, GV3D)... N.O. + N.C. 1 GV3A01 23.80... N.O. + N.O. 1 GV3A02 23.80... N.O. + N.O. + N.C. 1 GV3A03 23.80... N.O. + N.O. + N.O. 1 GV3A05 23.80... N.O. + N.O. + 2 Term. connect. 1 GV3A06 23.80... N.O. + N.C. + 2 Term. connect. 1 GV3A07 23.80... N.C. 1 GV3A08 23.80... N.O. 1 GV3A09 23.80Rated Voltage–660 VacModel Inrush Sealed Pick-Up Voltage Drop-Out Voltage Operating TimehGV2AU 12 VA / 8 W 3.5 VA / 1.1 W 0.8 to 1.1 0.35 to 0.7 10 to 15 msGV2AS 14 VA / 10.5 W 5 VA / 1.6 W 0.7 to 1.1 0.2 to 0.75 10 to 15 msGV3B 12 VA / 7 W 7 VA / 2.5 W 0.8 to 1.1 0.7 to 0.35 10 msGV3D 12 VA / 7 W 7 VA / 2.5 W 0.8 to 1.1 0.7 15 msFor additional information, reference Catalog #2520CT0001R9/02.16-526/19/06I11DiscountSchedule© 2006 Schneider ElectricAll Rights Reserved6/19/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!