13.07.2015 Views

Tab 16.book - Piti Group

Tab 16.book - Piti Group

Tab 16.book - Piti Group

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TeSys D-Line Contactor AccessoriesElectronic Timers and Interface Moduleswww.SquareD.comFor the most up-to-date informationThe following accessories require use of cabling accessories (LAD4BBtt) for proper mounting. See page 16-7.Electronic Serial Timer ModulesThese solid state modules delay the energizing and de-energizing of the contactor coil.TypeOperational Voltagea24–250 Vac 100–250 Vac 24–250 Vac-dcOn-delay LC1D09–D32 LC1D40–D150 LP1D09–D32Time Delaya For 24 V operation, the contactor must be fitted with a 21 V coil: code Z5 for 50 Hz, Z6 for 60 Hz, ZD for DC.CatalogNumberPrice0.1–2 s LA4DT0U $82.001.5–30 s LA4DT2U 82.0025–500 s LA4DT4U 82.00LA4DFBInterface ModulesThese modules allow the contactor coils to be energized from low voltage and low current level signals. They comein mechanical relay and solid state versions. The relay plus manual operation versions include a lever for manuallyturning the contactor on and off. When a module receives a low level signal, it allows the separate sourced controlvoltage to flow to the contactor coil. It saves space and wiring time compared to conventional interposing relays.InterfaceTypeOperational Voltage24–250 Vac 100–250 Vac 24–250 VdcInputVoltageCatalogNumberRelayLC1D09–D150 LP1D09–D32 24 V LA4DFB $55.00LC1D09–D150 LP1D09–D32 48 V LA4DFE 55.00Relay Plus LC1D09–D150 LP1D09–D32 24 V LA4DLB 71.00Manual Operation LC1D09–D150 LP1D09–D32 48 V LA4DLE 71.00Solid State LC1D09–D32 LC1D40–D115 24 V LA4DWB 71.00PriceLA4DMUAutomatic-Manual-Stop Control ModulesThese modules allow for local and/or remote operation of the contactor coil. Each module includes a lever toswitch from automatic to manual operation and a dial to turn the contactor on and off.Operational VoltageCatalog24–100 Vac 100–250 Vac 24–100 Vdc 100–250 VdcNumberPriceLC1D09–D150 . . . LP1D09–D32 . . . LA4DMK $35.00. . . LC1D09–D150 . . . LP1D09–D32 LA4DMU 35.00IEC STYLE CONTACTORSAND STARTERS16LADLVRTA1A2LADLVRTA1E1LAD4BBContactors 32 A and lessA1E1Contactors 40 A–80 AE21.8547A2E21.2532A2SEMI F47 Low Voltage Ride Through ModuleBy ensuring SEMI F47 compliance of AC powered IEC contactors and relays, the low voltage ride throughmodules can be used to increase the voltage sag immunity of semiconductor processing equipment. Thesemodules make it possible for AC powered TELEMECANIQUE contactors and relays to exceed the requirementsof SEMI F47, both in the magnitude and duration of a voltage sag event—even with accessories such as auxiliarycontact blocks and pneumatic timers.The low voltage ride through modules can be used with TELEMECANIQUE contactors from 9 A through 80 A, aswell as the CAD series of control relays.For use on: Catalog Number PriceLC1DttB7, CADttB7 LADLVRT24Vb $124.00LC1DttG7, CADttG7 LADLVRT120Vb 124.00LC1DttLE7, CADttLE7 LADLVRT208Vb 124.00Top mount bracket (required when using above modules) LAD4BBc 23.00Fuse LA9D941 60.00b The low voltage ride through module can be used with all TeSys control relays with 24 Vac, 120 Vac or 208 Vac dual frequency coils.c LAD4BB must be used when the low voltage ride through module is being used with contactors 32 A and less, and TeSys CAD Series of ControlRelays.For additional information, reference Catalog #8502CT9901R5/03.16-83/12/04I12DiscountSchedule© 2004 Schneider ElectricAll Rights Reserved3/12/04

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!