6.4 Installing an Oil CartridgeInstalling an oil cartridge is similar to that for grease,as described in Section 6.3, but the oil cartridgecannot be placed upside down on the red housingwithout spilling. First, lift the black rubber seal backand place the battery pack into the red housing (note:the Giga model, shown at left, does not use rubberseal). Insert the identification label, spring, andcompression plate into the transparent housing.Next, hold the oil cartridge delicately in one handand place the red housing on the neck of thecartridge. While holding the oil cartridge firmly onthe red housing, reverse their position. Place the red housing and cartridge on a hardsurface and place transparent housing on top. Lock as instructed in Section 6.2.2.6.5 Testing the MEMOLUB ® HPS (Check Function)To ensure that the MEMOLUB ® HPS is working, gently pushon one of the three switches at the bottom of the red housing fora few seconds. The MEMOLUB ® HPS will then go through anejection cycle. This will confirm that electronics, mechanics andbatteries are okay. It is important that this be done only with alubricant cartridge installed. Operating the MEMOLUB ® HPSwithout a cartridge or with an empty cartridge will “un-prime”the pump (refer to Section 6.3: Installing a Grease Cartridge).6.6 Mounting the MEMOLUB ® HPS onto the MEMOScrew the MEMOLUB ® HPS lubricator onto theMEMO (which should already be screwed into thebearing housing) using care not to damage the threads.Once the MEMOLUB ® HPS is mounted onto theMEMO, it will immediately start one or two ejectioncycles. This is the test function.6.7 Testing the MEMOLUB ® HPS (While Mounted)The MEMOLUB ® HPS can be checked at any time while in operation. To do so, unscrewthe MEMOLUB ® HPS from the MEMO approximately one turn and then screw it backdown (hand-tight). If the unit is working properly, it will immediately complete oneejection cycle. If, due to a noisy environment, it is not possible to hear the MEMOLUB ®HPS functioning during this test, unscrew the MEMOLUB ® HPS completely from theMEMO, go to a quieter location, and follow the instructions in Section 6.5.6.8 MaintenanceThe MEMOLUB ® HPS does not require any specific maintenance. When used in humidMEMOLUB ® HPS User’s <strong>Guide</strong> Page 16 of 39 <strong>PLI</strong>, <strong>LLC</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!