Lubrication SystemsMEM LUB ® 2-Point MEMOLUB ® SystemSPLT-0307-PG4 Copyright©2006 <strong>PLI</strong>, <strong>LLC</strong> All Rights ReservedHow the Splitter MEMO WorksThe Valve Stem is maintained in the upper position by the spring. When the MEMOLUB® HPS ejects lubricant,the MEMOLUB® HPS pump piston simultaneously pushes the Valve Stem downwards. Lubricant flows throughthe hollow Valve Stem and, as shown in stage 1, out through Outlet 1. As the Valve Stem moves downwards,Outlet 1 is closed and Outlet 2 opens allowing lubricant to flow through it, as shown in stage 2. Upon completionof the output cycle the Return Spring pushes the Valve Stem into the upper position to complete the cycle.Stage 1Stage 2Discharge PortCap3.31"84mmValve StemReturn SpringBodyOutlet 2Outlet 1Outlet 2Outlet 11.57"40mm1.22"31mmMounting DimensionsGigaMegaStandardMEMOLUB MEI MEIMEI7.5" (19cm)8.75" (22.23cm)12" (30.48cm)4.00" 4.75"10.16cm12.07cmMEMOLUB® <strong>User's</strong> <strong>Guide</strong> Page 29 of 39 <strong>PLI</strong>, <strong>LLC</strong>