Amended July 2011, see page 3 Rules for High Speed, Light Craft and Naval Surface Craft, January 2011Pt.3 Ch.3 Sec.7 – Page 35SECTION 7PILLARS AND PILLAR BULKHEADSA. GeneralA 100 Introduction101 In this section requirements for pillars and for bulkhead stiffeners substituting pillars are given.A 200 Definitions201 Symbols:L, B, D, T, C B , see Ch.1.t = thickness of plating in mms = stiffener spacing in m, measured along platel = length of pillars, cross ties, bulkhead stiffeners etc. between effective supports normal to their axis in mI = smallest moment of inertia in cm 4 , including 40 x plate thickness as flange for bulkhead stiffenerA = cross-sectional area in cm 2 , including 40 x plate thickness for bulkhead stiffenerp = design pressure as given in Ch.1.B. PillarsB 100 Arrangement of pillars101 Where practicable, deck pillars are to be located in line with pillars above or below.If arrangement with pillars in line is not possible, deck beams or girders will have to be reinforced.102 Pillars or equivalent supports are to be arranged below deckhouses, windlasses, winches and other heavyweights.103 The engine room casing is to be supported.104 Doubters are to be fitted on deck and inner bottom, except in tanks where doublers are not allowed.Brackets may be used instead of doublers. Where pillar tension may occur, brackets are required.105 Structural reinforcement below pillars will be considered in the individual cases.B 200 Cross-section particulars201 The radius of gyration of a member is to be taken as:I a= moment of inertia as built in cm 4 about the axis perpendicular to the expected direction of bucklingA a = cross-sectional area as built in cm 2 .If the end conditions are different with respect to the principle axes of the member, the i-value may have to bechecked for both axes.B 300 Pillar scantlings301 The cross-sectional area of members subjected to compressive loads is not to be less than:η =Plikk--------------- minimum 0,3 l1 + - iiA==I----- a( c m )A a10 P---------- ( cm 2 )ησ c= axial load in kN as given for various strength members in 302 and 303. Alternatively, P may beobtained from direct stress analysis. See Sec.9 D= length of member in m= radius of gyration in cm= 0.7 in general<strong>DET</strong> <strong>NORSKE</strong> <strong>VERITAS</strong> AS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!