SM-6495 - Ansaldo STS
SM-6495 - Ansaldo STS
SM-6495 - Ansaldo STS
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
General Maintenance and TroubleshootingNOTE 1:ADD JUMPER 2C-5CFOR GATE DOWN IND.NOTE 2:ADD JUMPER 2C-6C FOR POS.XRP OR 4B-6C FOR NEG. XRP.NOTE 3:DASHED WIRES INDICATEUSER WIRING.OPTIONAL} HEATERINDICATION(SEE NOTE 1)GATE DOWNXRP(SEE NOTE 2)UNION SWITCH & SIGNAL(WHT)+3A2A1AA1MCR-5A 6A4ABOSCH (BLK)C1SEE NOTE 4.FUNCTIONCLOSEDCONTACTTEST LINK0 - 89 DEG MOTOR UP1 FRONTBETWEEN 5B & 6BOPENS WITH GOLDNUT LOOSENED.6B5B4B3B2B1BC7/A7(F1/F2)N12B12UPCONTROLC8/A8VACANT SLOTMOTOR DN46 - 93 DEG4C3C2C5C1CC9/A9(H1/H2)6CBELLGATE DN INDFLASH'G LIGHT5 - 93 DEG0 - 5 DEG83 - 90 DEG(B2)23456(BLU)2S-214710(RED)POWERDOWNMODULE25811AUXCIRCUITBATC10/A10(F3/F4)BREAKER(H3/H4)C11/A112S-136912C12/A12MOMENTARYSWITCH(B4)T7T6(IS)T5NOTE 4:POLARITYT4R2 R3REVERSINGRELAY TERMINATIONS AS SHOWNT3 T2 T1SWITCH ARE FOR PN-150HD.SNUB LIMLETTERS IN PARENTHESIS ARE+ RES RESFOR NON-VITAL RELAY.HC(BRAKE)-R4R1SNUBDIODEMOTORMODEL 95 GATE MECHANI<strong>SM</strong>WIRING DIAGRAM FOR NON-V ITAL PED MECHUNITS WITH MAINT. SWITCH & HEATERGATE ARMLIGHT TERMS LABEL PART NO. M46717301 /US&S DWG. C467173 REV.1NOTE: T6 AND T7ONLY APPLY TORETROFIT KITN46709202C467173 R1Figure 2-6 - Wiring Diagram for Pedestrian Mechanism 12-Volt Systems withMaintenance Switch<strong>SM</strong> <strong>6495</strong>, Rev. 7, December 2008 2-13