ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - <strong>SERVICE</strong> MANUALWIRING DIAGRAM120 VAC 1ØPower SupplyGroundNeutralHotService Notes - Polarity & GroundThis water heater is polarity and ground sensitive. The control system will lock out anddisplay a fault message (“AC Reversed”) if the power supply polarity is reversed. Flamesensing current cannot be established if the burner is not grounded which will lead to ignitionfailure. See electrical requirements on page 8.Technical Literature Department 39 of 52 Ashland City, TN © 2008Servicing should only be performed by a Qualified Service Agent