Liquid <strong>fi</strong><strong>ltration</strong><br />
cooltexx | Cellulose-polyester media<br />
Key data<br />
<strong>Product</strong>ion process<br />
Wet-laid nonwoven process<br />
Material<br />
Cellulose + Polyester<br />
Bonding<br />
Chemical<br />
Max. width<br />
2.3 m<br />
B<strong>and</strong> <strong>fi</strong>lter principle<br />
Gravitation <strong>and</strong> where appropriate vacuum<br />
Machining process Grinding / honing / lapping [ <strong>fi</strong>ne-smoothing ]<br />
Application<br />
Filter media with a cellulose content are used predominantly in aqueous solutions,<br />
where a low pressure drop is a primary consideration, e. g. with pure gravity<br />
systems. The hydrophilic properties of the cellulose ensure good wettability for<br />
water, so that despite the <strong>fi</strong>ne <strong>fi</strong>bers used <strong>and</strong> the good particle arrestance only<br />
a low pressure drop ensues. Since cellulose can be bonded only chemically, not<br />
thermally, the mechanical strengths will usually be lower than with polyester spunbonded<br />
nonwovens, so that their use is restricted to systems with low tensile<br />
stresses.<br />
<strong>Product</strong> advantages<br />
• Hydrophilic <strong>fi</strong>ne-<strong>fi</strong>ber medium with good water wettability<br />
• Long operational lifetime thanks to depth-loading <strong>fi</strong><strong>ltration</strong><br />
• Low pressure drop thanks to good wettability<br />
• High separation ef<strong>fi</strong>cacy, even with <strong>fi</strong>ne particles<br />
Article<br />
Weight per unit area<br />
[ g / m² ]<br />
<strong>Air</strong>-permeability at<br />
100 Pa<br />
[ l / s x m² ]<br />
Pore size:<br />
Largest pore / MFP<br />
[ µm ]<br />
cooltexx 2652 17 3000 > 200 0.19<br />
cooltexx 2653 23 1900 300 / 160 0.19<br />
cooltexx 2654 32 1500 230 / 100 0.28<br />
cooltexx 2662 25 4000 > 200 0.28<br />
cooltexx 2663 50 1800 250 / 130 0.37<br />
cooltexx 2666 60 1600 220 / 130 0.45<br />
cooltexx 2693 70 2000 200 / 100 0.53<br />
cooltexx 2689 130 1000 140 / 75 1.0<br />
Thickness<br />