YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Accessories<br />
Dust removal | Filtering Aid FHM 1500<br />
Application<br />
In what application categories does precoating with FHM 1500 offer<br />
advantages?<br />
Important: Precoating <strong>and</strong> compression without cleaning. In accordance with<br />
the relevant DIN safety data sheet, wearing a respirator mask of protection<br />
level FFP1 is recommended when h<strong>and</strong>ling the FHM 1500.<br />
• Plasma / flame <strong>and</strong> laser-cutting of metals<br />
• Welding<br />
• Cleanable “police <strong>fi</strong>lter” stages<br />
• Sticky dusts<br />
• Coating processes like spray-galvanizing, spray-aluminizing<br />
• Applications with low raw-gas concentrations<br />
Why precoating?<br />
• To improve the cleaning characteristics<br />
• For lower stable pressure drops<br />
How is precoating performed with FHM 1500?<br />
• With Filtering Aid 1500 as a one-off routine on new <strong>fi</strong>lter cartridges<br />
(approx. 10 g / m 2 )<br />
• Precoating duration: Minimum 15 min. compression with process dust to<br />
2000–2500 Pa<br />
Subject to technical changes.<br />
Article number<br />
Article<br />
53301586 Filtering Aid 1500 1.0<br />
Weight<br />
[ kg ]<br />
117<br />
www.freudenberg-<strong>fi</strong>lter.com