Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
1-2 Installation/Wiring<br />
Mounting Considerations<br />
• Mount the drive upright on a flat, vertical and level surface.<br />
– Install on 35 mm DIN Rail (for frames A and B).<br />
or<br />
– Install with screws.<br />
Table 1.A Screw Mounting Recommendations<br />
Minimum Panel Thickness Screw Size Mounting Torque<br />
1.9 mm (0.0747 in.) M4 (#8-32) 1.56-1.96 N-m (14-17 lb.-in.)<br />
• Protect the cooling fan by avoiding dust or metallic particles.<br />
• Do not expose to a corrosive atmosphere.<br />
• Protect from moisture and direct sunlight.<br />
Minimum Mounting Clearances<br />
Refer to Appendix B for mounting dimensions.<br />
Airflow<br />
Closest object that<br />
may obstruct air flow<br />
through the drive<br />
heat sink and chassis<br />
Ambient Operating Temperatures<br />
Table 1.B Enclosure and Clearance Requirements<br />
Horizontal Clearance between drives<br />
Ambient Temperature<br />
Minimum Maximum<br />
0 mm and greater -10°C (14°F) 40°C (104°F)<br />
25 mm and greater -10°C (14°F) 50°C (122°F)<br />
Drive enclosure is rated IP20, NEMA/UL Type Open.<br />
See Table 1.B<br />
76.2 mm (3.0 in.)<br />
76.2 mm (3.0 in.)<br />
76.2 mm (3.0 in.)<br />
76.2 mm (3.0 in.)