10<br />

Reliable emergency lighting requires<br />

a well thought concept.<br />

Engineering projects always create the same<br />

questions on installation, cost efficiency<br />

and connection to building management<br />

systems coming to the emergency<br />

lighting design. INOTEC Sicherheitstechnik<br />

offers experience, know-how and<br />

outstanding technical products.<br />

To produce light and illuminate all exit<br />

paths sufficiently - these are the main<br />

features for emergency lighting<br />

systems in case of a mains fail<br />

condition or in an emergency<br />

situation. The building owner has to<br />

make certain, that these functions are<br />

perfectly working - even after years.<br />

Regular tests, maintenance and service<br />

are one backbone to ensure reliable<br />

function of all emergency lighting<br />

system components.<br />

Inline with national standards regulare<br />

visual checks, functiontests and system<br />

duration tests have to be performed.<br />

Test data and all relevant system<br />

information must be kept in a<br />

log-book.<br />

Lamps must be replaced and new<br />

batteries have to be installed.<br />

This can create, depending on the<br />

building size and the installed system,<br />

quite substantial costs. The long-term<br />

spending sometimes outrun the initial<br />

costs by a long way. This should be<br />

considered to find the most favourable<br />

solution when starting the project<br />

engineering.<br />

Batt.-Operation<br />

Operation<br />

Failure<br />

1 2 3 4 5 6 FS 24V RTG B SL<br />

To limit the expected costs and freeze<br />

the safety level at the highest point we<br />

use the INOTEC <strong>SV</strong>-monitoring system.<br />

Batt.-Operation<br />

Failure<br />

Charging failure<br />

Remote Control<br />

Emergency lighting systems and<br />

connected components bearing this<br />

prefix test and monitor themselves.<br />

The results can be displayed, printed or<br />

Operation<br />

stored.<br />

Menue<br />

Enter<br />

Change<br />

Test<br />

Luminaries+<br />

Em-light system<br />

kwh<br />

Visual test<br />

Routine<br />

test<br />

+ -<br />

Lamps<br />

Battery<br />

+ -<br />

CH1 CH2 CH3 CH4<br />

L N L N L N L N<br />

Maintenance<br />

Light Switch<br />

Indicator<br />

+ -<br />

3,15 AT<br />

<strong>ELS</strong> - <strong>SV</strong><br />

Advantages of monitored emergency lighting systems<br />

FT<br />

DT<br />

Investscosts<br />

Energy costs<br />

Labour costs<br />

visual check<br />

Labour costs<br />

FT/DT<br />

Material costs<br />

3,15 AT<br />

Labour costs<br />

for testing<br />

.<br />

230V / AC<br />

output<br />

50 / 60 Hz 1<br />

PE N L Maintenance NLPE<br />

2<br />

NLPE<br />

3<br />

NLPE<br />

4<br />

NLPE<br />

Labour costs<br />

costs<br />

3,15 AT<br />

3,15 AT<br />

Operation<br />

costs<br />

3,15 AT<br />

Lighting<br />

system<br />

costs