12<br />

DPÜ - Three Phase Monitor<br />

To detect phase- or circuit failures in general<br />

lighting sub-distribution panels<br />

With volt-free failure indication contact<br />

· LED-indication for L1, L2, L3<br />

· free selectable phase connections<br />

· 1 change-over contact<br />

· monitoring low voltage and mains failure<br />

in three-phase networks<br />

· for single-phase monitoring too<br />

acc. to IEC 255<br />

· for DIN rail mounting<br />

For the connection to INOTEC central- and<br />

group supply battery systems.<br />

Voltage: 230V/400V AC 50/60 Hz<br />

Threshold 0,85 x UN<br />

Perm. temp.: -20°C ... +60°C<br />

EMC protected to 55015<br />

Dimension: H =58, W = 17,5, D = 90(mm)<br />

MTB - Mimic Panel<br />

Three LED, controlled via volt-free <strong>ELS</strong><br />

contacts, indicate<br />

- mains operation<br />

- battery operation<br />

- sum-failure<br />

These LED-indicators are, even in case of a<br />

mains failure, supplied from the <strong>ELS</strong>-<strong>SV</strong>.<br />

Key switch with free programmable functions<br />

- maintained light On/Off<br />

- emergency light On/Off<br />

Protection class: IP54<br />

For wall mounting<br />

Dimensions: H=110, W=200, D=115 (mm)<br />

Power-Mode with INOTEC-EVG´s<br />

Programming for 1 h<br />

max discharge current 17Ah=10A / 34Ah=20A, Imax =6A circuit<br />

EVG-Type EVG 4-6 <strong>SV</strong> EVG 4-13 <strong>SV</strong> EVG 18<strong>SV</strong> N-EVG<br />

36/100<br />

Lamp T16 T16 T16 TC-DEL TC-EL TC-DEL T16 TC-DEL TC-DEL T26 T26<br />

Load 4W 6W 8W 10W 11W 13W 18W 18W 26W 32W 50W<br />

Light output ratio 70% 70% 70% 100% 100% 100% 100% 100% 100% 100% 100%<br />

1 Lamps<br />

2 Lamps<br />

3 Lamps<br />

4 Lamps<br />

5 Lamps<br />

6 Lamps<br />

7 Lamps<br />

8 Lamps<br />

9 Lamps<br />

10 Lamps<br />

11 Lamps<br />

12 Lamps<br />

13 Lamps<br />

14 Lamps<br />

15 Lamps<br />

45<br />

47<br />

58<br />

N-EVG<br />

58/100<br />

0,31 0,40 0,51 0,71 0,72 0,83 1,02 1,12 1,56 1,88 2,86<br />

0,49 0,67 0,88 1,28 1,31 1,52 1,91 2,10 2,97 3,63 5,59<br />

0,66 0,93 1,25 1,86 1,89 2,22 2,79 3,08 4,39 5,37 - - -<br />

0,83 1,19 1,62 2,43 2,47 2,91 3,67 4,06 5,81 - - - - - -<br />

1,00 1,45 1,99 3,00 3,05 3,60 4,55 5,04 - - - - - - - - -<br />

1,18 ,72 2,36 3,57 3,64 4,29 5,44 - - - - - - - - - - - -<br />

1,35 1,98 2,73 4,14 4,22 4,98 - - - - - - - - - - - - - - -<br />

1,53 2,24 3,10 4,72 4,80 5,68 - - - - - - - - - - - - - - -<br />

1,70 2,50 3,47 5,29 5,39 - - - - - - - - - - - - - - - - - -<br />

1,87 2,77 3,84 5,86 5,97 - - - - - - - - - - - - - - - - - -<br />

2,05 3,03 4,22 - - - - - - - - - - - - - - - - - - - - - - - -<br />

2,22 3,29 4,59 - - - - - - - - - - - - - - - - - - - - - - - -<br />

2,37 3,55 4,96 - - - - - - - - - - - - - - - - - - - - - - - -<br />

2,56 3,82 5,33 - - - - - - - - - - - - - - - - - - - - - - - -<br />

2,74 4,08 5,70 - - - - - - - - - - - - - - - - - - - - - - - -<br />

<strong>ELS</strong>/<strong>SV</strong><br />

Components and technical data<br />

MTB - Mimic Panel<br />

Three LED, controlled via volt-free <strong>ELS</strong><br />

contacts, indicate<br />

- mains operation<br />

- battery operation<br />

- sum-failure<br />

These LED-indicators are, even in case of a<br />

mains failure, supplied from the <strong>ELS</strong>-<strong>SV</strong>.<br />

Key switch with free programmable functions<br />

- maintained light On/Off<br />

- emergency light On/Off<br />

Protection class: IP20<br />

For recessed wall mounting<br />

Dimensions: ø 90 (mm), D = 6,5 mm<br />

Notlicht<br />

Betrieb<br />

Störung Batt.-Betrieb<br />

Ein<br />

17,5 90<br />

200 70 6,5<br />

115<br />

165<br />

90<br />

INOTEC<br />

Safe-Mode with INOTEC-EVG`s<br />

Programming for 3 h<br />

max discharge current 17Ah=4,3A/34Ah=8,6A<br />

Aus<br />

74<br />

EVG 4-6 <strong>SV</strong> EVG 4-13 <strong>SV</strong> EVG 18<strong>SV</strong><br />

T16 T16 T16 TC-DEL TC-EL TC-DEL T16 TC-DEL<br />

4W 6W 8W 10W 11W 13W 18W 18W<br />

32% 32% 32% 50% 50% 50% 50% 50%<br />

0,24 0,28 0,31 0,43 0,43 0,48 0,58 0,63<br />

0,34 0,41 0,48 0,71 0,73 0,82 1,02 1,12<br />

0,44 0,55 0,65 1,00 1,02 1,16 1,46 1,61<br />

0,54 0,68 0,82 1,28 1,32 1,50 1,91 2,10<br />

0,64 0,82 0,98 1,57 1,61 1,84 2,35 2,59<br />

0,74 0,95 1,15 1,86 1,91 2,18 2,79 - - -<br />

0,84 1,09 1,32 2,14 2,20 2,52 3,23 - - -<br />

0,94 1,22 1,49 2,43 2,49 2,86 3,67 - - -<br />

1,04 1,36 1,66 2,71 2,79 3,20 - - - - - -<br />

1,14 1,49 1,83 3,00 3,08 3,55 - - - - - -<br />

1,24 1,63 2,00 3,29 3,38 3,89 - - - - - -<br />

1,34 ,76 2,17 3,57 3,67 - - - - - - - - -<br />

1,44 1,90 2,34 3,86 3,96 - - - - - - - - -<br />

1,54 2,03 2,50 - - - - - - - - - - - - - - -<br />

1,64 2,17 2,67 - - - - - - - - - - - - - - -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!