<strong>ELS</strong> - <strong>SV</strong><br />
JOKER - Technology<br />
Joker-technology function<br />
Each <strong>ELS</strong>-<strong>SV</strong> change-over device is<br />
able to foster three differing luminaire<br />
switching modes on the same output<br />
at the same time (see page 4).<br />
In addition to the system, luminaries<br />
with Joker high frequency electronic<br />
ballast (common standard on INOTEC<br />
luminaries) or Joker switch modules,<br />
J/<strong>SV</strong>-module/S, for third party<br />
electronic ballast, must be used.<br />
These components allow the easy<br />
setting of monitoring address and<br />
luminaire mode.<br />
The patented JOKER-technology of<br />
INOTEC reduces the design- and<br />
installation time and cuts down on<br />
material cost.<br />
The sample to the right shows the<br />
reduction on installation material and<br />
circuit layout.<br />
Conventional emergency lighting<br />
sys-tems and installations with the<br />
three possible standard switching<br />
modes maintained (DL)-,<br />
non-maintained (BL)- and switched<br />
maintained (gDL) mode, require 6 final<br />
end circuits to feed 9 luminaries in a<br />
part of the building shown.<br />
The Joker-Technology reduces the<br />
number of circuits required. Our sample<br />
needs only 2 final end circuits to feed<br />
the same number of luminaries due to<br />
the fact that the operation of all switching<br />
modes on one circuit is possible.<br />
The maintained and switched<br />
main-tained luminaries are active<br />
during mains presence. During mains<br />
failure however, all luminaries will be<br />
switched on and supplied by the<br />
battery (see page 6).<br />
Advantages of the Joker-technology<br />
Simple design and engineering<br />
Reduced installation material<br />
content (cable reductions, see page<br />
6 - non-maintained mode, sense<br />
input)<br />
Conventional installation<br />
requires<br />
6 final end circuits<br />
circuit 5<br />
circuit 6<br />
circuit 1<br />
Joker-technology with<br />
2 final end circuits<br />
circuit 3 circuit 4<br />
Maintained mode Non-maintained<br />
mode<br />
Cut down on installation time<br />
Higher load level for final end<br />
circuits<br />
Switching mode settable on each<br />
luminaire<br />
circuit 2<br />
circuit 1 circuit 2<br />
Switched maintained<br />
mode<br />
5