<strong>ELS</strong> - <strong>SV</strong><br />

JOKER - Technology<br />

Joker-technology function<br />

Each <strong>ELS</strong>-<strong>SV</strong> change-over device is<br />

able to foster three differing luminaire<br />

switching modes on the same output<br />

at the same time (see page 4).<br />

In addition to the system, luminaries<br />

with Joker high frequency electronic<br />

ballast (common standard on INOTEC<br />

luminaries) or Joker switch modules,<br />

J/<strong>SV</strong>-module/S, for third party<br />

electronic ballast, must be used.<br />

These components allow the easy<br />

setting of monitoring address and<br />

luminaire mode.<br />

The patented JOKER-technology of<br />

INOTEC reduces the design- and<br />

installation time and cuts down on<br />

material cost.<br />

The sample to the right shows the<br />

reduction on installation material and<br />

circuit layout.<br />

Conventional emergency lighting<br />

sys-tems and installations with the<br />

three possible standard switching<br />

modes maintained (DL)-,<br />

non-maintained (BL)- and switched<br />

maintained (gDL) mode, require 6 final<br />

end circuits to feed 9 luminaries in a<br />

part of the building shown.<br />

The Joker-Technology reduces the<br />

number of circuits required. Our sample<br />

needs only 2 final end circuits to feed<br />

the same number of luminaries due to<br />

the fact that the operation of all switching<br />

modes on one circuit is possible.<br />

The maintained and switched<br />

main-tained luminaries are active<br />

during mains presence. During mains<br />

failure however, all luminaries will be<br />

switched on and supplied by the<br />

battery (see page 6).<br />

Advantages of the Joker-technology<br />

Simple design and engineering<br />

Reduced installation material<br />

content (cable reductions, see page<br />

6 - non-maintained mode, sense<br />

input)<br />

Conventional installation<br />

requires<br />

6 final end circuits<br />

circuit 5<br />

circuit 6<br />

circuit 1<br />

Joker-technology with<br />

2 final end circuits<br />

circuit 3 circuit 4<br />

Maintained mode Non-maintained<br />

mode<br />

Cut down on installation time<br />

Higher load level for final end<br />

circuits<br />

Switching mode settable on each<br />

luminaire<br />

circuit 2<br />

circuit 1 circuit 2<br />

Switched maintained<br />

mode<br />