14<br />

J-EVG 4-6 <strong>SV</strong><br />

J-EVG 4-13 <strong>SV</strong><br />

J-EVG 18 <strong>SV</strong><br />

Compensated high frequency electronic<br />

ballast<br />

for fluorescent and compact fluorescent<br />

lamps TL/TC/TCD-EL 4-18 W, with easy<br />

accessible address switch, JOKER function<br />

and individual lamp monitoring.<br />

The JOKER function allows luminaries to be<br />

operated in maintained and<br />

non-maintained mode on the same final<br />

end circuit.<br />

Automatic deactivation of electronics in<br />

case of lamp failure.<br />

Suitable for emergency lighting systems<br />

to EN 50171 / EN 50172.<br />

Designed to be installed inside of<br />

luminaires.<br />

For the connection to INOTEC low poweror<br />

central power battery systems like <strong>ELS</strong><br />

or CPS.<br />

Voltage:<br />

230V AC 50/60 Hz<br />

220V DC ±20 %<br />

Perm. temp.: -15°C ... +50°C<br />

EMC protected to EN 55015<br />

40 4<br />

3 28<br />

<strong>ELS</strong>/<strong>SV</strong><br />

<strong>Electronic</strong> ballast's and <strong>SV</strong>-luminaire modules with JOKER-Technology<br />

J-EVG 4-6 <strong>SV</strong>/S<br />

J-EVG 4-13 <strong>SV</strong>/S<br />

J-EVG 18 <strong>SV</strong>/S<br />

Compensated high frequency electronic<br />

ballast<br />

for fluorescent and compact fluorescent<br />

lamps TL/TC/TCD-EL 4-18 W, with easy<br />

accessible address switch, JOKER function<br />

and individual lamp monitoring. This<br />

electronic ballast features a sense-input<br />

or an inverted phase monitor too.<br />

J-EVG 4-6 <strong>SV</strong> designed for low power loss<br />

at 4 Watt.<br />

The JOKER/S function allows luminaires to<br />

be operated in maintained, non-maintained<br />

and switched mode on the same final end<br />

circuit. Automatic deactivation of<br />

electronics in case of lamp failure.<br />

Suitable for emergency lighting systems<br />

to EN 50171 / EN 50172.<br />

Designed to be installed inside of<br />

luminaires. For the connection to INOTEC<br />

low power- or central power battery<br />

systems like <strong>ELS</strong> or CPS.<br />

Voltage:<br />

230V AC 50/60 Hz<br />

220V DC ±20 %<br />

Perm. temp.: -15°C ... +50°C<br />

EMC protected to EN 55015<br />

Individual lamp monitoring<br />

Component Type Joker technology Load Sense-input Treshhold Order number<br />

J-EVG 4-6 <strong>SV</strong> EVG yes 4-6W no 860008<br />

J-EVG 4-13 <strong>SV</strong> EVG yes 4-13W no 860004<br />

J-EVG 18 <strong>SV</strong> EVG yes 18W no 861003<br />

J-EVG 4-6 <strong>SV</strong>/S EVG yes 4-6W yes 860010<br />

J-EVG 4-13 <strong>SV</strong>/S EVG yes 4-13W yes 860005<br />

J-EVG 18 <strong>SV</strong>/S EVG yes 18W yes 861004<br />

<strong>SV</strong> Modul.1 Modul no 5-120W no<br />

Failure O.k<br />

< 10mA > 20mA 851001<br />

<strong>SV</strong> Modul.2 Modul no 20-300W no < 45mA > 70mA 851003<br />

J-<strong>SV</strong> Modul/S Modul yes 5-120W yes < 10mA > 20mA 851002<br />

J-<strong>SV</strong> Modul.2/S Modul yes 20-300W yes < 45mA > 70mA 851004<br />

J-<strong>SV</strong> Modul.3/S Modul yes 2-30W yes < 8mA > 12mA 851025<br />

J-<strong>SV</strong> Modul.4/S Modul yes 18-120W yes < 45mA > 70mA 851029<br />

J-<strong>SV</strong> Modul.L/S Modul yes 5-120W yes < 10mA > 20mA 851026<br />

J-<strong>SV</strong>-Modul/S<br />

J-<strong>SV</strong>-Modul.2/S<br />

J-<strong>SV</strong>-Modul.3/S<br />

J-<strong>SV</strong>-Modul.4/S<br />

J-<strong>SV</strong>-Modul.L/S<br />

Single luminaire monitoring module<br />

for fluorescent- (T16/T5…) compact<br />

fluorescent, halogen and incandescent<br />

lamps. With easy accessible address switch,<br />

JOKER function and individual lamp monitoring.<br />

This module features a sense-input or<br />

an inverted phase monitor too.<br />

The JOKER/S function allows luminaries to<br />

be operated via these J-<strong>SV</strong>-modules in<br />

maintained, non-maintained and switched<br />

mode on the same final end circuit.<br />

Suitable for emergency lighting systems to<br />

EN 50171 / EN 50172.<br />

Designed to be installed inside of luminaries.<br />

For the connection to INOTEC low<br />

power- or central power battery systems<br />

like <strong>ELS</strong> or CPS.<br />

Voltage:<br />

230 V AC, 50/60 Hz<br />

220 V DC, ±20 %<br />

Perm. temp.: -15°C ... +50°C<br />

EMC protected to EN 55015<br />

4,2<br />

4,2<br />

J-EVG 4-6/<strong>SV</strong><br />

J-EVG 4-13/<strong>SV</strong><br />

J-EVG 18/<strong>SV</strong><br />

240,4<br />

J-Modul/S<br />

J-<strong>SV</strong> Modul/S<br />

J-ET 9/24 <strong>SV</strong><br />

80<br />

90<br />

J-EVG 4-6/<strong>SV</strong>-S<br />

J-EVG 4-13/<strong>SV</strong>-S<br />

J-EVG 18/<strong>SV</strong>-S<br />

80<br />

90<br />

J-<strong>SV</strong> Modul.L/S<br />

J-<strong>SV</strong>-Modul.L/S<br />

235,4<br />

249,4<br />

40 4<br />

3 30<br />

17,9<br />

7<br />

26,4