Catalogue ELS/SV - Lumentron Electronic Kft.
Catalogue ELS/SV - Lumentron Electronic Kft.
Catalogue ELS/SV - Lumentron Electronic Kft.
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
14<br />
J-EVG 4-6 <strong>SV</strong><br />
J-EVG 4-13 <strong>SV</strong><br />
J-EVG 18 <strong>SV</strong><br />
Compensated high frequency electronic<br />
ballast<br />
for fluorescent and compact fluorescent<br />
lamps TL/TC/TCD-EL 4-18 W, with easy<br />
accessible address switch, JOKER function<br />
and individual lamp monitoring.<br />
The JOKER function allows luminaries to be<br />
operated in maintained and<br />
non-maintained mode on the same final<br />
end circuit.<br />
Automatic deactivation of electronics in<br />
case of lamp failure.<br />
Suitable for emergency lighting systems<br />
to EN 50171 / EN 50172.<br />
Designed to be installed inside of<br />
luminaires.<br />
For the connection to INOTEC low poweror<br />
central power battery systems like <strong>ELS</strong><br />
or CPS.<br />
Voltage:<br />
230V AC 50/60 Hz<br />
220V DC ±20 %<br />
Perm. temp.: -15°C ... +50°C<br />
EMC protected to EN 55015<br />
40 4<br />
3 28<br />
<strong>ELS</strong>/<strong>SV</strong><br />
<strong>Electronic</strong> ballast's and <strong>SV</strong>-luminaire modules with JOKER-Technology<br />
J-EVG 4-6 <strong>SV</strong>/S<br />
J-EVG 4-13 <strong>SV</strong>/S<br />
J-EVG 18 <strong>SV</strong>/S<br />
Compensated high frequency electronic<br />
ballast<br />
for fluorescent and compact fluorescent<br />
lamps TL/TC/TCD-EL 4-18 W, with easy<br />
accessible address switch, JOKER function<br />
and individual lamp monitoring. This<br />
electronic ballast features a sense-input<br />
or an inverted phase monitor too.<br />
J-EVG 4-6 <strong>SV</strong> designed for low power loss<br />
at 4 Watt.<br />
The JOKER/S function allows luminaires to<br />
be operated in maintained, non-maintained<br />
and switched mode on the same final end<br />
circuit. Automatic deactivation of<br />
electronics in case of lamp failure.<br />
Suitable for emergency lighting systems<br />
to EN 50171 / EN 50172.<br />
Designed to be installed inside of<br />
luminaires. For the connection to INOTEC<br />
low power- or central power battery<br />
systems like <strong>ELS</strong> or CPS.<br />
Voltage:<br />
230V AC 50/60 Hz<br />
220V DC ±20 %<br />
Perm. temp.: -15°C ... +50°C<br />
EMC protected to EN 55015<br />
Individual lamp monitoring<br />
Component Type Joker technology Load Sense-input Treshhold Order number<br />
J-EVG 4-6 <strong>SV</strong> EVG yes 4-6W no 860008<br />
J-EVG 4-13 <strong>SV</strong> EVG yes 4-13W no 860004<br />
J-EVG 18 <strong>SV</strong> EVG yes 18W no 861003<br />
J-EVG 4-6 <strong>SV</strong>/S EVG yes 4-6W yes 860010<br />
J-EVG 4-13 <strong>SV</strong>/S EVG yes 4-13W yes 860005<br />
J-EVG 18 <strong>SV</strong>/S EVG yes 18W yes 861004<br />
<strong>SV</strong> Modul.1 Modul no 5-120W no<br />
Failure O.k<br />
< 10mA > 20mA 851001<br />
<strong>SV</strong> Modul.2 Modul no 20-300W no < 45mA > 70mA 851003<br />
J-<strong>SV</strong> Modul/S Modul yes 5-120W yes < 10mA > 20mA 851002<br />
J-<strong>SV</strong> Modul.2/S Modul yes 20-300W yes < 45mA > 70mA 851004<br />
J-<strong>SV</strong> Modul.3/S Modul yes 2-30W yes < 8mA > 12mA 851025<br />
J-<strong>SV</strong> Modul.4/S Modul yes 18-120W yes < 45mA > 70mA 851029<br />
J-<strong>SV</strong> Modul.L/S Modul yes 5-120W yes < 10mA > 20mA 851026<br />
J-<strong>SV</strong>-Modul/S<br />
J-<strong>SV</strong>-Modul.2/S<br />
J-<strong>SV</strong>-Modul.3/S<br />
J-<strong>SV</strong>-Modul.4/S<br />
J-<strong>SV</strong>-Modul.L/S<br />
Single luminaire monitoring module<br />
for fluorescent- (T16/T5…) compact<br />
fluorescent, halogen and incandescent<br />
lamps. With easy accessible address switch,<br />
JOKER function and individual lamp monitoring.<br />
This module features a sense-input or<br />
an inverted phase monitor too.<br />
The JOKER/S function allows luminaries to<br />
be operated via these J-<strong>SV</strong>-modules in<br />
maintained, non-maintained and switched<br />
mode on the same final end circuit.<br />
Suitable for emergency lighting systems to<br />
EN 50171 / EN 50172.<br />
Designed to be installed inside of luminaries.<br />
For the connection to INOTEC low<br />
power- or central power battery systems<br />
like <strong>ELS</strong> or CPS.<br />
Voltage:<br />
230 V AC, 50/60 Hz<br />
220 V DC, ±20 %<br />
Perm. temp.: -15°C ... +50°C<br />
EMC protected to EN 55015<br />
4,2<br />
4,2<br />
J-EVG 4-6/<strong>SV</strong><br />
J-EVG 4-13/<strong>SV</strong><br />
J-EVG 18/<strong>SV</strong><br />
240,4<br />
J-Modul/S<br />
J-<strong>SV</strong> Modul/S<br />
J-ET 9/24 <strong>SV</strong><br />
80<br />
90<br />
J-EVG 4-6/<strong>SV</strong>-S<br />
J-EVG 4-13/<strong>SV</strong>-S<br />
J-EVG 18/<strong>SV</strong>-S<br />
80<br />
90<br />
J-<strong>SV</strong> Modul.L/S<br />
J-<strong>SV</strong>-Modul.L/S<br />
235,4<br />
249,4<br />
40 4<br />
3 30<br />
17,9<br />
7<br />
26,4