12.8 nanoe-G Operation<br />

� This operation provides clean air by producing great amount of negative ions and distribute through the<br />

discharge airflow to capture or deactivate molds, bacteria or viruses.<br />

� nanoe-G operation start condition<br />

o During unit running at any operation mode, if nanoe-G operation is activated, combination operation<br />

(operation mode + nanoe-G operation) starts.<br />

o During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts.<br />

� nanoe-G operation stop condition<br />

o When OFF/ON button is pressed to stop the operation.<br />

o When nanoe-G button is pressed.<br />

o When OFF Timer activates.<br />

� nanoe-G operation pause condition<br />

o When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after<br />

indoor fan restarts.<br />

o When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°C<br />

continuously for 30 minutes.<br />

� <strong>Indoor</strong> fan control<br />

o During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.<br />

However, nanoe-G system enabled when fan speed ≥ 500rpm to ensure proper negative ion distribution,<br />

nanoe-G system disabled when fan speed < 500 rpm.<br />

o During nanoe-G individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if Fan<br />

Speed button is pressed, no signal is sent to the unit and no change on remote control display. Auto Fan<br />

Speed for nanoe-G operation changes from SHi to Hi after 4 hours of operation.<br />

� Airflow direction control<br />

o During any operation mode combines with nanoe-G operation, airflow direction follows respective operation<br />

mode.<br />

o During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no<br />

signal is sent to the unit and no change on remote control display.<br />

� Timer control<br />

o When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G<br />

operation status.<br />

o When ON Timer activates during any operation, no change on current operation.<br />

o When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status<br />

is saved.<br />

� Indicator<br />

o When nanoe-G starts, nanoe-G indicator ON.<br />

� Remote Control Receiving Sound<br />

o Normal Operation � nanoe-G Operation : Beep<br />

o Nanoe-G Operation � Normal Operation : Beep<br />

o Stop � nanoe-G individual Operation : Beep<br />

o Nanoe-G individual Operation � Stop : Long Beep<br />

� Power failure<br />

o During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individual<br />

operation resumes immediately.<br />

o During combination operation, if power failure occurs, after power resumes, combination operation resume<br />

immediately.<br />

o nanoe-G operation status is not memorized after OFF the unit. After OFF the unit, when the operation is ON<br />

again, air conditioner operates without nanoe-G operation.<br />