12.10.3.6 Sunlight Sensor Abnormality<br />

� Abnormality detection:<br />

o When ECONAVI is ON, if the sunlight intensity value below minimum level continuously for 24 hours, the<br />

sunlight sensor disconnection error counter will increase by 1 time. If the ECONAVI is OFF, the 24 hours<br />

timer will be reset, but the sunlight sensor disconnection error counter will not be reset.<br />

� Error Code judgment<br />

o When sunlight sensor disconnection error counter reached 15 times. H70 occurred.<br />

o No TIMER indicator or ECONAVI indicator blink.<br />

� When error code happened, the unit is able to operate without sunlight sensor.<br />