Indoor Unit Outdoor Unit CS-E24NKES CS-E28NKES CU-E24NKE ...
Indoor Unit Outdoor Unit CS-E24NKES CS-E28NKES CU-E24NKE ...
Indoor Unit Outdoor Unit CS-E24NKES CS-E28NKES CU-E24NKE ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
12.10.3.6 Sunlight Sensor Abnormality<br />
� Abnormality detection:<br />
o When ECONAVI is ON, if the sunlight intensity value below minimum level continuously for 24 hours, the<br />
sunlight sensor disconnection error counter will increase by 1 time. If the ECONAVI is OFF, the 24 hours<br />
timer will be reset, but the sunlight sensor disconnection error counter will not be reset.<br />
� Error Code judgment<br />
o When sunlight sensor disconnection error counter reached 15 times. H70 occurred.<br />
o No TIMER indicator or ECONAVI indicator blink.<br />
� When error code happened, the unit is able to operate without sunlight sensor.<br />
49