09.12.2012 Views

InstallShield 2012 Express Edition User Guide - Knowledge Base ...

InstallShield 2012 Express Edition User Guide - Knowledge Base ...

InstallShield 2012 Express Edition User Guide - Knowledge Base ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 25: Errors and Warnings<br />

Build Errors and Warnings<br />

Build Errors and Warnings<br />

The table below provides troubleshooting tips for each build error and warning.<br />

Table 25-2: Build Errors and Warnings<br />

Error Description Troubleshooting Tips<br />

-32000 Build canceled by the user. This error occurs only when the build is terminated during the build<br />

process.<br />

-7256 To digitally sign a software<br />

identification tag file, .NET<br />

Framework 2.0 or later must be<br />

installed.<br />

-7255 Only .pfx files can be used to<br />

digitally sign a software<br />

identification tag file.<br />

-7236 <strong>InstallShield</strong> could not create the<br />

software identification tag because<br />

the value for the %1 setting in the<br />

General Information view is invalid.<br />

Ensure that it does not contain any<br />

of the following characters:<br />

\ / : * ? " < > |<br />

-7235 <strong>InstallShield</strong> could not create the<br />

software identification tag because<br />

the %1 setting in the General<br />

Information view is empty.<br />

If your project is configured to include a software identification tag<br />

and if the release that you are building is configured to use a .pfx<br />

file to digitally sign your release, <strong>InstallShield</strong> attempts to digitally<br />

sign the tag that it creates at build time. If your build machine does<br />

not have .NET Framework 2.0 or later, this build warning is<br />

displayed.<br />

To resolve this build warning, install .NET Framework 2.0 on your<br />

build machine.<br />

If your project is configured to include a software identification tag<br />

and if the release that you are building is configured to use an .spc<br />

file and a .pvk file to digitally sign your release, <strong>InstallShield</strong><br />

generates this build warning.<br />

To resolve this build warning, switch from an .spc file and a .pvk file<br />

to a .pfx file. If you do not need to have a digitally signed tag, you<br />

can ignore this warning.<br />

<strong>InstallShield</strong> uses the values that you enter for the Unique ID and<br />

Tag Creator ID settings as part of the name of the tag file<br />

(TagCreatorID_UniqueID.swidtag). Therefore, the ID that you<br />

enter must not contain any characters that are invalid for file<br />

names.<br />

To resolve this issue, enter a valid value in the setting that is<br />

mentioned in the warning message.<br />

For more information, see Including a Software Identification Tag<br />

for Your Product.<br />

Creation of a software identification tag requires that several<br />

settings in the General Information view have values. To resolve this<br />

warning, enter the appropriate value in the setting that is mentioned<br />

in the warning message, or select No for the Use Software<br />

Identification Tag setting.<br />

For more information, see Including a Software Identification Tag<br />

for Your Product.<br />

610 ISE-1800-UG01 <strong>InstallShield</strong> <strong>2012</strong> <strong>Express</strong> <strong>Edition</strong> <strong>User</strong> <strong>Guide</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!