09.12.2012 Views

InstallShield 2012 Express Edition User Guide - Knowledge Base ...

InstallShield 2012 Express Edition User Guide - Knowledge Base ...

InstallShield 2012 Express Edition User Guide - Knowledge Base ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 25: Errors and Warnings<br />

Build Errors and Warnings<br />

Table 25-2: Build Errors and Warnings (cont.)<br />

Error Description Troubleshooting Tips<br />

-6258 An error occurred extracting digital<br />

signature information from file "%1".<br />

Make sure the digital signature<br />

information provided in the IDE is<br />

correct.<br />

-6257 The build engine has detected that<br />

PRODUCT_NAME has been defined<br />

in your project. At run time, your<br />

installation will display this value as<br />

your Product Name instead of the<br />

Product Name values defined in the<br />

IDE.<br />

Ensure that the digital signature information is correct. You can<br />

access the digital signature information on the Signing tab in the<br />

Releases view.<br />

This warning message occurs when the ID PRODUCT_NAME has<br />

been defined in the string table. This string table ID overrides the<br />

Product Name values set in the General Information view. Check<br />

article Q109136, "ERRDOC: Build Error -6257, in the <strong>Knowledge</strong><br />

<strong>Base</strong> for information on how to resolve this error.<br />

-6255 Internal build error Check the <strong>Knowledge</strong> <strong>Base</strong> for information about this error, or<br />

request technical support.<br />

-6254 An error occurred building the<br />

MsiFileHash table for File %1<br />

Check the <strong>Knowledge</strong> <strong>Base</strong> for information about this error, or<br />

request technical support.<br />

-6253 Internal build error Check the <strong>Knowledge</strong> <strong>Base</strong> for information about this error, or<br />

request technical support.<br />

-6252 Internal build error Check the <strong>Knowledge</strong> <strong>Base</strong> for information about this error, or<br />

request technical support.<br />

-6251 Internal build error. Check the <strong>Knowledge</strong> <strong>Base</strong> for information about this error, or<br />

request technical support.<br />

-6250 Internal build error. Check the <strong>Knowledge</strong> <strong>Base</strong> for information about this error, or<br />

request technical support.<br />

-6248 Could not find dependent file %1 of<br />

feature %2<br />

-6247 The .NET Framework redistributable<br />

%1 is not found on the system. %2<br />

The missing file is required by the feature’s key file. Make sure the<br />

missing file is on the build system in the same directory as the<br />

feature’s key file.<br />

If the dependency is not required, you can turn off .NET<br />

dependency scanning for the feature. To turn off dependency<br />

scanning, set the feature’s .NET Scan at Build property to None or<br />

Properties Only.<br />

Download the <strong>InstallShield</strong> .NET Update from http://<br />

www.installshield.com/products/dotnet.asp.<br />

If you have the Visual Studio release candidate, you can copy<br />

dotnetfx.exe from Windows Feature Update CD, in the<br />

dotnetframework directory, to <strong>InstallShield</strong> Program Files<br />

Folder\Redist\0409\i386.<br />

624 ISE-1800-UG01 <strong>InstallShield</strong> <strong>2012</strong> <strong>Express</strong> <strong>Edition</strong> <strong>User</strong> <strong>Guide</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!