11.07.2018 Views

CONSTRUCTION CHEMICALS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MegaSıva Elyaflı K<br />

Cement Based, Manually Applied Roughcast With<br />

Fiber Additive<br />

PRODUCT DESCRIPTION<br />

White cement based, manually applied roughcast with fiber with enhanced adherence, which<br />

contains filling material of suitable granulometry and which has been reinforced with various<br />

chemical additives.<br />

AREAS OF USE<br />

MegaSıva Elyaflı K is used in indoors and outdoors spaces for the elimination of surface<br />

defects and the repair of the fractures and cracks and the smoothing of surfaces on prime<br />

coated gas concrete, prime coated concrete, briquette, brick surfaces and ceilings, for the<br />

gauging of wall surfaces with defective gauge, and for surface smoothing prior to such<br />

applications as insulation system and curtain walling systems.<br />

PRODUCT ADVANTAGES<br />

• Resistant to outdoor conditions.<br />

• Ensuring high bonding to the surface, the product does not cause spalling and poses high<br />

bonding strength.<br />

• Being a high performance product, it does not cause contraction thanks to the fiber additive<br />

content.<br />

• Prepared and applied easily.<br />

PERFORMANCE<br />

Dry bulk density 1.60 ± 0.1 gr/cm 3 TS EN 1015 - 10<br />

Compressive strength CS IV TS EN 1015 - 11<br />

Bonding strength > 0.5 N/mm 2 TS EN 1015 - 12<br />

Capillary water absorption<br />

coefficient<br />

W 1 TS EN 1015 - 18<br />

Water vapor permeability µ < 11 TS EN 1015 - 19<br />

Air content % 6.5 ± 0.5 TS EN 1015 - 7<br />

> 3.5 hours (at 20 ± 5°C<br />

Workability time<br />

temperature and minimum 95 % TS EN 1015 - 9<br />

relative humidity)<br />

Reaction to fire A1 TS EN 13501 - 1<br />

The foregoing values represent the results of the laboratory tests conducted at 23 ± 2°C<br />

temperature and 50% ± 5 relative humidity conditions. The values provided as per the table<br />

may vary depending on the surface and ambient conditions.<br />

REFERENCE STANDARDS<br />

Certifications/Standards<br />

TS EN 998 - 1 (GP)<br />

Ministry of Public Works and Settlement Item No.<br />

Ministry of Public Works and Settlement Item No.: 04.482<br />

QUALITY CERTIFICATES<br />

Conformant to TS EN 998 - 1.<br />

CE<br />

APPLICATION PROCEDURE<br />

Application Surfaces<br />

Indoors and Outdoors Walls;<br />

- Gas concrete (MegaFilm primer applied)<br />

- Concrete (MegaFilm or MegaFilm BB primer applied)<br />

- Briquette<br />

- Brick<br />

Ceilings:<br />

- Concrete (MegaFilm or MegaFilm BB primer applied)<br />

Surface Preparation<br />

• The application surface should be dry, clean, sound and dust free, and should have been<br />

cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as<br />

mortar and cement residues should be scraped from the application surface.<br />

• The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or<br />

MegaTamir K 24 hours in advance. In the cases, where structural repair mortar should be<br />

used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.<br />

• The application surfaces should be moisturized with water, where necessary.<br />

• Upon the completion of the surface cleaning, MegaFilm primer should be applied in a<br />

single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding<br />

strength and stabilize the surface absorption.<br />

• Gas concrete surfaces should, prior to the application of the product, be applied MegaFilm<br />

primer and the water absorption of the surfaces should so be reduced.<br />

• Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in<br />

single coat and be left to dry for minimum 3 hours prior to the application of the adhesive<br />

mortar in order to enhance the adhesion strength.<br />

Application Methods<br />

• The application thickness should ranger between 1.0 cm and 2.5 cm. In the cases where the<br />

application thickness is to exceed 2.5 cm, an additional coat of maximum 2 cm thickness<br />

should be applied upon the sufficient hardening of the primary coat.<br />

• The product should be applied with a steel trowel, whereupon the surface should be<br />

smoothened with a gauge stick.<br />

• Once plaster dewaters and is sufficiently hardened following the application, the surface<br />

should be processed with a trowel and final finishing touches should be made with a moist<br />

sponge.<br />

Application Recommendations<br />

• The surface should be moisturized intermittently for a period 7 days following the<br />

application in order to enhance the endurance of the plaster.<br />

• Plaster profiles should be employed on the corners in order to ensure a better quality result<br />

and high level of efficiency.<br />

• The product should not be applied to such surfaces, to which paint, premixed colorful<br />

plaster, base coat plaster or exterior coating, and to gypsum surfaces.<br />

• The product should, once mixed, be used before the expiration of its pot life. Any product,<br />

the pot life of which has expired, should not be used during the application.<br />

• Any such foreign substance as lime, cement or plaster should not be added to the mortar<br />

prepared.<br />

• Any extra water should not be added to the mixture.<br />

• The product should not be applied on unsound surfaces. The soundness and the load<br />

bearing capacity of old surfaces should be checked prior to adhesion.<br />

• The surface should be preserved from air currents and water contact during and after the<br />

application.<br />

• The product should not be applied to such surfaces, which are exposed to risk of freezing<br />

within the next 24 hours, which are frozen or the frost of which is thawing.<br />

• Due care should be taken to ensure that the material is not exposed to direct sunlight in hot<br />

weather conditions, and the product should be mixed with cold water.<br />

• The product should not be applied on extremely windy weather conditions or on hot<br />

surfaces, which are exposed to direct sunlight; and in the cases, where application is<br />

imperative under such conditions, the environment and the surface should be prepared for<br />

application in advance.<br />

• The product should not be applied in rainy weather conditions, and the application surface<br />

should be preserved from rain for a period of 24 hours.<br />

• Refer to our technical support hotline for recommendation on different surface applications.<br />

(PHONE: 444 4 595)<br />

Surface and Ambient Temperature<br />

The surface and ambient temperature should be between +5°C and +30°C whilst at<br />

application.<br />

Application Limits<br />

Useful time for prepared mortar - Pot life<br />

Plaster surface smoothing time<br />

Through dry time<br />

The foregoing values represent the results of the laboratory tests conducted at 23 ± 2°C<br />

temperature and 50% ± 5 relative humidity conditions. The values provided as per the table<br />

may vary depending on the surface and ambient conditions.<br />

APPLICATION INSTRUCTIONS<br />

Mixing Ratio<br />

The product should be mixed with water, weighing equal to 23 - 25 % of the product. (8.00<br />

- 8.75 liters of water for a 35 kg package)<br />

Mixing Equipment<br />

• Low speed electrical mixer (400 cycles/min.)<br />

• Special tip stirring equipment<br />

Mixing Period<br />

The product should be stirred with a low-speed mixer until any dry dust and globs are<br />

eliminated. The mortar should, then, be stirred once again for 1 to 2 minutes after being had<br />

settled for 3 to 4 minutes following preparation.<br />

Application Equipment<br />

• Steel trowel<br />

• Smoothing trowel<br />

• Sponge<br />

Equipment Cleaning<br />

The equipment used should be cleaned with water following the application before the<br />

mortar dries.<br />

TECHNICAL PROPERTIES<br />

Chemical Structure: Cement based plaster with fiber additive<br />

Dry Density: 1.60 ± 0.1 gr/cm 3<br />

Mortar Density: 1.80 ± 0.1 gr/cm 3<br />

Grain Size: ≤ 1800 µm<br />

Coat Thickness: Maximum 1.0 cm - 2.5 cm (single coat)<br />

Color: White<br />

Maximum 1 hour<br />

Maximum 40 minutes<br />

Minimum 2 days<br />

126

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!