11.07.2018 Views

CONSTRUCTION CHEMICALS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MegaSıva Thermo<br />

Plaster Mortar For Thermal Insulation Panels<br />

PRODUCT DESCRIPTION<br />

Cement based, easily applicable thermal insulation panel plaster reinforced with polymer<br />

additives.<br />

AREAS OF USE<br />

MegaSıva Thermo is used as the surface plaster on such thermal insulation panels as XPS,<br />

platinum, EPS and rockwool in indoors and outdoors spaces of all buildings.<br />

PRODUCT ADVANTAGES<br />

• Poses high level of adherence on the thermal insulation panels thanks to the special<br />

additives in its content.<br />

• Prevents condensation and winds the system thanks to its high vapor permeability.<br />

• Prevents the formation of cracks and spalling thanks to the fibers in its content.<br />

• Prepared and applied easily.<br />

PERFORMANCE<br />

Hollow specific bulk gravity of fresh mortar > 1150 kg/m 3 TS EN 1015 - 6<br />

Hollow specific bulk gravity of hardened<br />

cement based mortar<br />

1450 ± 200 kg/m 3 TS EN 1015 - 10<br />

Water absorption < 0.5 kg/m 2 dk 0,5 TS EN 1015 - 18<br />

Bending strength > 2 N/mm 2 TS EN 1015 - 11<br />

Compressive strength > 6 N/mm 2 TS EN 1015 - 11<br />

Sieve analysis (in excess of 1 mm) Maksimum 1 % TS EN 1015 - 1<br />

Adhesion strength to thermal insulation<br />

panel<br />

> 0.08 N/mm 2 TS EN 13494<br />

Water vapor permeability coefficient µ ≤ 15 TS EN 1015 - 19<br />

Reaction to fire A1 TS EN 13501 - 1<br />

The foregoing values represent the results of the laboratory tests conducted at 23 ± 2°C<br />

temperature and 50% ± 5 relative humidity conditions. The values provided as per the table<br />

may vary depending on the surface and ambient conditions.<br />

REFERENCE STANDARDS<br />

Certifications/Standards<br />

TSE K 113<br />

Ministry of Public Works and Settlement Item No.<br />

Ministry of Public Works and Settlement Item No.: 04.481<br />

QUALITY CERTIFICATES<br />

TSEK<br />

CE<br />

APPLICATION PROCEDURE<br />

Application Surfaces<br />

Indoors and Outdoors Walls;<br />

- XPS<br />

- EPS<br />

- Platinum<br />

- Rockwool<br />

Surface Preparation<br />

• The application surface should be dry, clean, sound and dust free, and should have been<br />

cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as<br />

mortar and cement residues that impair the surface smoothness should be scraped from the<br />

application surface.<br />

• When used as leveling plaster; the surface defects, which are deeper than 1 cm, should be<br />

repaired with MegaTamir İ or MegaTamir K 24 hours in advance. In the cases, where<br />

structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should<br />

be preferred.<br />

Application Methods<br />

• MegaSıva Thermo should be applied with a steel trowel in equal thickness on all surfaces.<br />

• Donatı Filesi should, following the application of the primary coat of MegaSıva Thermo,<br />

be placed into the plaster by stretching the mesh thoroughly and applying slight pressure<br />

thereon from top to bottom, preventing any foldings.<br />

• The joints of Donatı Filesi should be superpositioned by 10 cm in order to prevent the<br />

formation of cracks. In the event the corner profiles are mesh free; the glass fiber mesh should<br />

be turned by minimum 20 cm on the corners.<br />

• The primary coat with mesh should be let dewater slightly before the application of the<br />

secondary coat.<br />

• The surface will have become ready for the finishing coat applications minimum 7 days after<br />

the secondary coat plaster application.<br />

Application Recommendations<br />

• Plaster profiles should be employed on the corners in order to ensure a better quality result<br />

and high level of efficiency.<br />

• The product should, once mixed, be used before the expiration of its pot life. Any product,<br />

the pot life of which has expired, should not be used during the application.<br />

• Any such foreign substance as lime, cement or plaster should not be added to the mortar<br />

prepared.<br />

• Any extra water should not be added to the mixture.<br />

• The product should not be applied on unsound surfaces. The soundness and the load bearing<br />

capacity of old surfaces should be checked prior to adhesion.<br />

• The surface should be preserved from air currents and water contact during and after the<br />

53 application.<br />

133<br />

• The product should not be applied to such surfaces, which are exposed to risk of freezing<br />

within the next 24 hours, which are frozen or the frost of which is thawing.<br />

• Due care should be taken to ensure that the material is not exposed to direct sunlight in hot<br />

weather conditions, and the product should be mixed with cold water.<br />

• The product should not be applied on extremely windy weather conditions or on hot<br />

surfaces, which are exposed to direct sunlight; and in the cases, where application is<br />

imperative under such conditions, the environment and the surface should be prepared for<br />

application in advance.<br />

• The product should not be applied in rainy weather conditions, and the application surface<br />

should be preserved from rain for a period of 24 hours.<br />

• Refer to our technical support hotline for recommendation on different surface applications.<br />

(PHONE: 444 4 595)<br />

Surface and Ambient Temperature<br />

The surface and ambient temperature should be between +5°C and +30°C whilst at<br />

application.<br />

Application Limits<br />

Useful time for prepared mortar - Pot life<br />

Required stand - by period for final coat<br />

The foregoing values represent the results of the laboratory tests conducted at 23 ± 2°C<br />

temperature and 50% ± 5 relative humidity conditions. The values provided as per the table<br />

may vary depending on the surface and ambient conditions.<br />

APPLICATION INSTRUCTIONS<br />

Mixing Ratio<br />

The product should be mixed with water, weighing equal to 24 - 26 % of the product. (6.0 -<br />

6.5 liters of water for a 25 kg package)<br />

Mixing Equipment<br />

• Low speed electrical mixer (400 cycles/min.)<br />

• Special tip stirring equipment<br />

Mixing Period<br />

The product should be stirred with a low-speed mixer until any dry dust and globs are<br />

eliminated. The mortar should, then, be stirred once again for 1 to 2 minutes after being had<br />

settled for 3 to 4 minutes following preparation.<br />

Application Equipment<br />

• Steel trowel<br />

• Smoothing trowel<br />

Maximum 2 hours<br />

Minimum 7 days<br />

Equipment Cleaning<br />

The equipment used should be cleaned with water following the application before the<br />

mortar dries.<br />

TECHNICAL PROPERTIES<br />

Chemical Structure: Cement based plaster mortar with polymer and fiber additive<br />

Dry Density: 1.50 ± 0.1 gr/cm 3<br />

Mortar Density: 1.75 ± 0.1 gr/cm 3<br />

Grain Size: ≤ 600 µm<br />

Coat Thickness: 2 - 5 mm (for the primary and the secondary coats)<br />

Color: Gray<br />

CONSUMPTION<br />

The recommended consumption amount for a 4 mm thick insulation application (primary<br />

coat of mortar + Donatı Filesi + secondary coat of mortar) on 1 m 2 surface is 4.0 - 5.0 kg.<br />

The said values may vary, depending on the surface and ambient conditions.<br />

PACKAGING<br />

MegaSıva Thermo is delivered in net 25 kg kraft bags, which are stowed in 54 pcs. on a 80<br />

cm x 100 cm palette (1350 kg).<br />

SHELF LIFE<br />

The shelf life of the product is 12 months when stored within non-tampered original<br />

packaging in dry (maximum relative humidity 60 %) and cool (ambient temperature between<br />

+5°C and +25°C) environment.<br />

STORAGE CONDITIONS<br />

The product should be stored within non-tampered original packaging in dry (maximum relative<br />

humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment.<br />

It should not be exposed to direct sunlight.<br />

The container of the product should be closed firmly when not used.<br />

SAFETY PRECAUTIONS<br />

Please refer to the Safety Data Sheet (SDS) as appropriate for easy and safe application.