CONSTRUCTION CHEMICALS
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
MegaSıva Thermo<br />
Plaster Mortar For Thermal Insulation Panels<br />
PRODUCT DESCRIPTION<br />
Cement based, easily applicable thermal insulation panel plaster reinforced with polymer<br />
additives.<br />
AREAS OF USE<br />
MegaSıva Thermo is used as the surface plaster on such thermal insulation panels as XPS,<br />
platinum, EPS and rockwool in indoors and outdoors spaces of all buildings.<br />
PRODUCT ADVANTAGES<br />
• Poses high level of adherence on the thermal insulation panels thanks to the special<br />
additives in its content.<br />
• Prevents condensation and winds the system thanks to its high vapor permeability.<br />
• Prevents the formation of cracks and spalling thanks to the fibers in its content.<br />
• Prepared and applied easily.<br />
PERFORMANCE<br />
Hollow specific bulk gravity of fresh mortar > 1150 kg/m 3 TS EN 1015 - 6<br />
Hollow specific bulk gravity of hardened<br />
cement based mortar<br />
1450 ± 200 kg/m 3 TS EN 1015 - 10<br />
Water absorption < 0.5 kg/m 2 dk 0,5 TS EN 1015 - 18<br />
Bending strength > 2 N/mm 2 TS EN 1015 - 11<br />
Compressive strength > 6 N/mm 2 TS EN 1015 - 11<br />
Sieve analysis (in excess of 1 mm) Maksimum 1 % TS EN 1015 - 1<br />
Adhesion strength to thermal insulation<br />
panel<br />
> 0.08 N/mm 2 TS EN 13494<br />
Water vapor permeability coefficient µ ≤ 15 TS EN 1015 - 19<br />
Reaction to fire A1 TS EN 13501 - 1<br />
The foregoing values represent the results of the laboratory tests conducted at 23 ± 2°C<br />
temperature and 50% ± 5 relative humidity conditions. The values provided as per the table<br />
may vary depending on the surface and ambient conditions.<br />
REFERENCE STANDARDS<br />
Certifications/Standards<br />
TSE K 113<br />
Ministry of Public Works and Settlement Item No.<br />
Ministry of Public Works and Settlement Item No.: 04.481<br />
QUALITY CERTIFICATES<br />
TSEK<br />
CE<br />
APPLICATION PROCEDURE<br />
Application Surfaces<br />
Indoors and Outdoors Walls;<br />
- XPS<br />
- EPS<br />
- Platinum<br />
- Rockwool<br />
Surface Preparation<br />
• The application surface should be dry, clean, sound and dust free, and should have been<br />
cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as<br />
mortar and cement residues that impair the surface smoothness should be scraped from the<br />
application surface.<br />
• When used as leveling plaster; the surface defects, which are deeper than 1 cm, should be<br />
repaired with MegaTamir İ or MegaTamir K 24 hours in advance. In the cases, where<br />
structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should<br />
be preferred.<br />
Application Methods<br />
• MegaSıva Thermo should be applied with a steel trowel in equal thickness on all surfaces.<br />
• Donatı Filesi should, following the application of the primary coat of MegaSıva Thermo,<br />
be placed into the plaster by stretching the mesh thoroughly and applying slight pressure<br />
thereon from top to bottom, preventing any foldings.<br />
• The joints of Donatı Filesi should be superpositioned by 10 cm in order to prevent the<br />
formation of cracks. In the event the corner profiles are mesh free; the glass fiber mesh should<br />
be turned by minimum 20 cm on the corners.<br />
• The primary coat with mesh should be let dewater slightly before the application of the<br />
secondary coat.<br />
• The surface will have become ready for the finishing coat applications minimum 7 days after<br />
the secondary coat plaster application.<br />
Application Recommendations<br />
• Plaster profiles should be employed on the corners in order to ensure a better quality result<br />
and high level of efficiency.<br />
• The product should, once mixed, be used before the expiration of its pot life. Any product,<br />
the pot life of which has expired, should not be used during the application.<br />
• Any such foreign substance as lime, cement or plaster should not be added to the mortar<br />
prepared.<br />
• Any extra water should not be added to the mixture.<br />
• The product should not be applied on unsound surfaces. The soundness and the load bearing<br />
capacity of old surfaces should be checked prior to adhesion.<br />
• The surface should be preserved from air currents and water contact during and after the<br />
53 application.<br />
133<br />
• The product should not be applied to such surfaces, which are exposed to risk of freezing<br />
within the next 24 hours, which are frozen or the frost of which is thawing.<br />
• Due care should be taken to ensure that the material is not exposed to direct sunlight in hot<br />
weather conditions, and the product should be mixed with cold water.<br />
• The product should not be applied on extremely windy weather conditions or on hot<br />
surfaces, which are exposed to direct sunlight; and in the cases, where application is<br />
imperative under such conditions, the environment and the surface should be prepared for<br />
application in advance.<br />
• The product should not be applied in rainy weather conditions, and the application surface<br />
should be preserved from rain for a period of 24 hours.<br />
• Refer to our technical support hotline for recommendation on different surface applications.<br />
(PHONE: 444 4 595)<br />
Surface and Ambient Temperature<br />
The surface and ambient temperature should be between +5°C and +30°C whilst at<br />
application.<br />
Application Limits<br />
Useful time for prepared mortar - Pot life<br />
Required stand - by period for final coat<br />
The foregoing values represent the results of the laboratory tests conducted at 23 ± 2°C<br />
temperature and 50% ± 5 relative humidity conditions. The values provided as per the table<br />
may vary depending on the surface and ambient conditions.<br />
APPLICATION INSTRUCTIONS<br />
Mixing Ratio<br />
The product should be mixed with water, weighing equal to 24 - 26 % of the product. (6.0 -<br />
6.5 liters of water for a 25 kg package)<br />
Mixing Equipment<br />
• Low speed electrical mixer (400 cycles/min.)<br />
• Special tip stirring equipment<br />
Mixing Period<br />
The product should be stirred with a low-speed mixer until any dry dust and globs are<br />
eliminated. The mortar should, then, be stirred once again for 1 to 2 minutes after being had<br />
settled for 3 to 4 minutes following preparation.<br />
Application Equipment<br />
• Steel trowel<br />
• Smoothing trowel<br />
Maximum 2 hours<br />
Minimum 7 days<br />
Equipment Cleaning<br />
The equipment used should be cleaned with water following the application before the<br />
mortar dries.<br />
TECHNICAL PROPERTIES<br />
Chemical Structure: Cement based plaster mortar with polymer and fiber additive<br />
Dry Density: 1.50 ± 0.1 gr/cm 3<br />
Mortar Density: 1.75 ± 0.1 gr/cm 3<br />
Grain Size: ≤ 600 µm<br />
Coat Thickness: 2 - 5 mm (for the primary and the secondary coats)<br />
Color: Gray<br />
CONSUMPTION<br />
The recommended consumption amount for a 4 mm thick insulation application (primary<br />
coat of mortar + Donatı Filesi + secondary coat of mortar) on 1 m 2 surface is 4.0 - 5.0 kg.<br />
The said values may vary, depending on the surface and ambient conditions.<br />
PACKAGING<br />
MegaSıva Thermo is delivered in net 25 kg kraft bags, which are stowed in 54 pcs. on a 80<br />
cm x 100 cm palette (1350 kg).<br />
SHELF LIFE<br />
The shelf life of the product is 12 months when stored within non-tampered original<br />
packaging in dry (maximum relative humidity 60 %) and cool (ambient temperature between<br />
+5°C and +25°C) environment.<br />
STORAGE CONDITIONS<br />
The product should be stored within non-tampered original packaging in dry (maximum relative<br />
humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment.<br />
It should not be exposed to direct sunlight.<br />
The container of the product should be closed firmly when not used.<br />
SAFETY PRECAUTIONS<br />
Please refer to the Safety Data Sheet (SDS) as appropriate for easy and safe application.