Megaİzo PK3/PK4 - PK3/PK4 Plus - PK3/PK4 Super Plus<br />
APP (Atactic Polypropylene) Modified, Plastomeric Bitumen, With Polyester<br />
Seal Carrier; (Megaİzo PK3/PK4, Megaİzo PK3/PK4 Plus) and SBS<br />
(Styrene-Butadiene-Styrene) Modified, Elastomeric Bitumen<br />
(Megaİzo PK3/PK4 Super Plus) Water Insulation Membrane<br />
PRODUCT DESCRIPTION<br />
Plastomeric/elastomeric bitumen water insulation membrane, coated with polyethylene film<br />
at both sides, the physical resistance of which has been increased by polyester seal.<br />
AREAS OF USE<br />
Suitable for use in foundations, bridges, viaducts, large size structures of art, tunnels, artificial<br />
ponds, water canals, waste storage areas, treatment plants and swimming pools.<br />
PRODUCT ADVANTAGES<br />
• Highly resistant to ruptures and tears.<br />
• Resistant to adverse impacts, which may arise in the soil.<br />
• Highly resistant to heavy building loads.<br />
• Megaİzo PK3 / PK4 is ideal for use in hot, temperate and moderate climate zones;<br />
Megaİzo PK3 / PK4 Plus is ideal for use in hot and cold (continental) climate zones;<br />
Megaİzo PK3 / PK4 Super Plus is ideal for use in cold climate zone<br />
• Megaİzo PK3 / PK4 is easily applicable under high temperature conditions; Megaİzo PK3<br />
/ PK4 Super Plus is easily applicable under low temperature conditions<br />
• Easily applied to such surfaces as chimney flashings and parapets.<br />
• Ensure waterproofing throughout the life cycle of the building.<br />
• Prior to the application, the consumption amount can be clearly and precisely determined.<br />
• Pose high level of resistance to ground waters, which contain hazardous chemicals such as<br />
sulfate.<br />
• Free from any hazardous materials. The products do not pose any threats to human health<br />
and the environment.<br />
• Elastic.<br />
PERFORMANCE<br />
PROPERTIES<br />
The foregoing values represent the results of the laboratory tests. The values provided as per<br />
the table may vary depending on the surface and ambient conditions.<br />
REFERENCE STANDARDS<br />
Certifications/Standards<br />
TS 11758 - 1<br />
NEW<br />
APPLICABLE<br />
STANDARD<br />
UNIT<br />
Ministry of Public Works and Settlement Item No.<br />
Ministry of Public Works and Settlement Item No:<br />
04.626/6A - 6F (Megaİzo PK3 / PK4)<br />
04.626/2A - 2G (Megaİzo PK3 / PK4 Plus)<br />
04.626/4A - 4G (Megaİzo PK3 / PK4 Super Plus)<br />
Megaİzo<br />
PK3 / PK4<br />
QUALITY CERTIFICATES<br />
TSE (Megaİzo PK3 / PK4, Megaİzo PK3 / PK4 Plus)<br />
Conformant to TS 11758 - 1. (Megaİzo PK3 / PK4 Super Plus)<br />
CE<br />
Megaİzo<br />
PK3 / PK4<br />
Plus<br />
Polyethylene<br />
film<br />
Polyethylene<br />
film<br />
Megaİzo<br />
PK3 / PK4<br />
Super Plus<br />
Polyethylene<br />
film<br />
Polyethylene<br />
film<br />
Top surface coating - -<br />
Polyethylene<br />
film<br />
Bottom surface<br />
Polyethylene<br />
- -<br />
coating<br />
film<br />
Reinforcement - - Polyester Polyester Polyester<br />
Temperature<br />
resistance<br />
TS EN 1110 °C 110 120 110<br />
Tensile strength<br />
(length/ width)<br />
TS EN 12311 - 1 N/5 cm 600/400 800/600 800/600<br />
Elongation at break<br />
(length/ width)<br />
TS EN 12311 - 1 % 30/30 35/35 35/35<br />
Cold bending TS EN 1109 °C<br />
- 5<br />
(minimum)<br />
- 10<br />
(minimum)<br />
- 20<br />
(minimum)<br />
APPLICATION PROCEDURE<br />
Surface Preparation<br />
• The application surface should be dry, clean, sound and dust free, and should have been<br />
cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as<br />
mortar and cement residues should be scraped from the application surface.<br />
• The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or<br />
MegaTamir K 24 hours in advance. In the cases, where structural repair mortar should be<br />
used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.<br />
• The molding oil residues on the concrete surface, if any, should be cleaned with high pressure<br />
water. The surface should, upon drying, be prepared for application with MegaFilm İzo.<br />
Application Methods<br />
• Edge and corner joints should be beveled with MegaTamir İ and MegaTamir K repair<br />
mortars in order for the maintenance of waterproofing.<br />
• The bottom surface of the cover should be molten with blowpipe flame, and should be<br />
adhered to make sure that the margin parts at joints overlap.<br />
• Margin parts should be allowed at the joint points by 10 cm on the width and by 15 cm on<br />
the length.<br />
• The membrane tiers should be formed perpendicularly in the same direction as the slope at<br />
all layers, and tusk tenon should be applied between any two tiers to ensure that the joint<br />
points do not overlap to the furthest extent possible.<br />
79<br />
Application Recommendations<br />
• Due care must be taken to make sure that the membrane selected is suitable for the<br />
prevailing climate conditions and the physical characteristics of the building.<br />
• Due care must be taken to make sure that all parts are adhered upon the completion of the<br />
application.<br />
• In cold weather conditions, the membrane should be kept in a warm environment prior to<br />
the application, and applied at such temperatures higher than +5°C.<br />
• The products should be applied in single coat or double coats for foundation waterproofing<br />
applications, depending on the ground water content of the soil, the prevailing geographical<br />
conditions of the region and the ground structure.<br />
• In the case of basement tanking application against pressure water, the products are,<br />
generally, recommended to be applied in double coats.<br />
• For roof insulation applications, if the slope is more than 5%, then one-coat of Megaİzo<br />
PK4, Megaİzo PK4 Plus or Megaİzo PK4 Super Plus could be applied according to the<br />
climate conditions and physical properties of the structures.<br />
• The insulation should be sandwiched between steel flanges at crossing spots, where the<br />
insulation is likely to be punctured.<br />
• Due care must be taken to ensure that the insulation material is not damaged by mechanical<br />
impacts in the cases of coating over the insulation.<br />
• The application surfaces should, with due consideration of the related details, be covered<br />
and protected with thermal insulation panels, drainage panels, geo-textile seal etc., and the<br />
application surface should never be left uncovered.<br />
• The product should not be applied on unsound surfaces. The soundness and the load-bearing<br />
capacity of old surfaces should be checked prior to adhesion.<br />
• The surface should be preserved from air currents and water contact during and after the<br />
application.<br />
• The product should not be applied to such surfaces, which are exposed to risk of freezing<br />
within the next 24 hours, which are frozen or the frost of which is thawing.<br />
• Due care should be given to prevent the exposure of the material to direct sunlight in hot<br />
weather conditions.<br />
• The product should not be applied on extremely windy weather conditions or on hot surfaces,<br />
which are exposed to direct sunlight; and in the cases, where application is imperative under<br />
such conditions, the environment and the surface should be prepared for application in<br />
advance.<br />
• The product should not be applied in rainy weather conditions, and the application surface<br />
should be preserved from rain for a period of 24 hours.<br />
• Refer to our technical support hotline for recommendation on different surface applications.<br />
(PHONE: 444 4 595)<br />
APPLICATION INSTRUCTIONS<br />
Application Equipment<br />
Blowpiper<br />
Trowel<br />
TECHNICAL PROPERTIES<br />
Chemical Structure: APP (atactic polypropylene) modified, plastomeric bitumen, with<br />
Polyester seal carrier; (Megaİzo PK3 / PK4, Megaİzo PK3 / PK4 Plus) and SBS (styrene<br />
-butadiene-styrene) modified, elastomeric bitumen (Megaİzo PK3 / PK4 Super Plus) water<br />
insulation membrane<br />
Thickness: 3 mm, 4 mm<br />
Roll Weight: 35 kg (3 mm), 45 kg (4 mm)<br />
Roll Dimensions (Width/Length): 10 m 2<br />
CONSUMPTION<br />
The recommended consumption amount varies, depending on the size of the application<br />
surface.<br />
PACKAGING<br />
Megaİzo PK3, Megaİzo PK3 Plus, Megaİzo PK3 Super Plus are delivered in the form 1<br />
meter wide and 10 meters long at total of 30 rolls on 100x120 cm sizes palette.<br />
Megaİzo PK4, Megaİzo PK4 Plus, Megaİzo PK4 Super Plus are delivered in the form 1<br />
meter wide and 10 meters long at total of 20 rolls on 100x120 cm sizes palette.<br />
STORAGE CONDITIONS<br />
The product should be stored within non-tampered original packaging in dry (maximum relative<br />
humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment in the<br />
form of rolls, stowed upright.<br />
It should not be exposed to direct sunlight.<br />
The product should be protected from UV lights and sudden changes in temperature.<br />
The product should not be stored in overlapping position.<br />
SAFETY PRECAUTIONS<br />
Please refer to the Safety Data Sheet (SDS) as appropriate for easy and safe application.