PArtner Article<br />

an intensity mA output that allow for a<br />

setpoint mA level to be set in a client’s<br />

DCS for both the pilot and flaring status<br />

signals levels from a single unit. Additional<br />

add-on features are also available<br />

for configuring the Quasar 2 system to<br />

meet a wide range of client flare types,<br />

monitoring requirements, and budgets.<br />

This product offers a new stainlesssteel<br />

enclosure for reduced corrosion<br />

and increased suitability for marine<br />

applications. Two models are available:<br />

Quasar 2 M8100-EXP and Quasar 2<br />

M8100-EXP Advanced. Scalable options<br />

are available with the advanced version<br />

including continuous 4-20 mA, peak<br />

hold and decay, and power supply with<br />

24V DC, and 85 to 265V AC input.<br />

High-resolution optics and selection of<br />

various spot sizes enables the Quasar<br />

2 to be positioned as far as 400 meters<br />

from the flare stack being monitored<br />

and ensure the highest flame signal<br />

detection. Alignment on the target is accomplished<br />

through the targeting port<br />

and the signal intensity LED bar displays<br />

amplitude in combination with a stable<br />

M-4 Heavy Duty Swivel Mount.<br />

Custom electronics adapt to target<br />

movement, varying luminosity, and most<br />

climate conditions. The alarm delay<br />

circuit can be adjusted for a specific location<br />

or application, eliminating false<br />

alarms from temporary loss of signal due<br />

to intermittent flames, adverse weather,<br />

and wind. The set point feature of the<br />

advanced unit can also be used for staged<br />

flares and will provide feedback on the<br />

staged flare status.<br />

Typical Applications for the use of<br />

Quasar 2 systems include:<br />

• Elevated Flares (either steam- airor<br />

gas- assisted)<br />

• Ground Flares (burn pit-flares,<br />

ground flare arrays)<br />

• Off-Shore Flares<br />

• Staged Flares<br />

LumaSense Technologies owns 25 years<br />

of experience in offering our Quasar<br />

Flare Stack monitoring pyrometer solution.<br />

With proven technology, reliable<br />

instrumentation and installations at<br />

over 550 petrochemical facilities worldwide,<br />

customers know they can trust the<br />

LumaSense E²T line of petrochemical<br />

infrared sensors.<br />

Flare monitoring<br />

from up to 400m<br />

away with the<br />

Quasar 2<br />

Quasar 2 instrument fixed on<br />

a rugged M-8 pedestal mount