17.12.2012 Views

120 mm. - Kühler Rath KG

120 mm. - Kühler Rath KG

120 mm. - Kühler Rath KG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

12V<br />

DC<br />

Test Voltage: 13,0 VOLT DC<br />

AXIAL FANS<br />

F07P-12EL8102/HT-02S Suction - Aspirante<br />

F07P-12EL8102/HT-02B Blowing - Soffiante<br />

<strong>mm</strong> Airflow Airflow Current Airflow Airflow Current <strong>mm</strong> Airflow Airflow Current Airflow Airflow Current<br />

inch inch<br />

H2O m3/h cfm/h Amp. m3/h cfm/h Amp . H2O m3/h cfm/h Amp. m3/h cfm/h Amp.<br />

0,0 0 2000 1180 12,8 1990 1170 12,2 0,0 0 2050 1210 6,1 1990 1170 5,9<br />

2,5 0,1 1870 1100 12,9 1850 1090 12,4 2,5 0,1 1890 1<strong>120</strong> 6,2 1860 1100 6,0<br />

5,0 0,2 1730 1020 12,9 1710 1010 12,5 5,0 0,2 1760 1040 6,2 1730 1020 6,0<br />

7,5 0,3 1560 920 12,9 1560 920 12,5 7,5 0,3 1610 950 6,2 1570 930 6,1<br />

10,0 0,4 1380 810 12,8 1370 810 12,5 10,0 0,4 1420 840 6,2 1400 830 6,1<br />

12,5 0,5 1150 680 12,4 1140 670 12,7 12,5 0,5 1210 710 6,1 1190 700 6,2<br />

15,0 0,6 820 480 12,6 890 530 12,7 15,0 0,6 940 550 6,1 940 550 6,3<br />

17,5 0,7 610 360 12,7 630 370 12,7 17,5 0,7 700 410 6,2 680 400 6,3<br />

20,0 0,8 470 280 12,8 160 90 12,5 20,0 0,8 540 320 6,3 310 180 6,1<br />

22,5 0,9 110 60 13,2 0 0 12,8 22,5 0,9 310 180 6,4 0 0 6,4<br />

25,0 1,0 0 0 13,2 25,0 1,0 0 0 6,5<br />

24V<br />

DC<br />

Static SUCTION<br />

BLOWING<br />

Static<br />

Pressure Aspirante Soffiante<br />

Pressure<br />

Aspirante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 1,70 Kg<br />

LOW NOISE<br />

®<br />

WEIGHT 1,70 Kg<br />

LOW NOISE<br />

The dimensions are in <strong>mm</strong>. ( 25,4 <strong>mm</strong>. = 1 inch )<br />

FAN DIAMETER<br />

Diametro Ventola<br />

For the Axial Fans exposed to the water, mounted with motor-up and blade-down, we reco<strong>mm</strong>end to require the<br />

2 holes for the water discharge on the blade hub. At the end of the fan description please write “2H”.<br />

Per Elettroventole esposte all’acqua, e montate con il motore sopra e la ventola sotto, si raccomanda di chiedere<br />

i 2 fori di drenaggio sul mozzo della ventola. Aggiungere alla fine della descrizione prodotto la sigla “2H”.<br />

F07P-24EL8102/HT-02B Blowing - Soffiante<br />

Test Voltage: 26,0 VOLT DC<br />

SUCTION<br />

280 <strong>mm</strong>.<br />

11 inch<br />

F07P-24EL8102/HT-02S Suction - Aspirante<br />

BLOWING<br />

Soffiante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!