12V<br />

DC<br />

Test Voltage: 13,0 VOLT DC<br />

AXIAL FANS<br />

F55-12L8205/HT-26S Suction-Aspirante<br />

<strong>mm</strong> Airflow Airflow Current Airflow Airflow Current <strong>mm</strong> Airflow Airflow Current Airflow Airflow Current<br />

inch inch<br />

H2O m3/h cfm/h Amp. m3/h cfm/h Amp . H2O m3/h cfm/h Amp. m3/h cfm/h Amp.<br />

24V<br />

DC<br />

Static SUCTION<br />

BLOWING<br />

Static<br />

Pressure Aspirante Soffiante<br />

Pressure<br />

Aspirante<br />

0 0 2960 1750 13,3 0 0 0 3030 1790 6,4 0<br />

5 0,2 2650 1560 14,5 0 5 0,2 2750 1620 7,1 0<br />

10 0,4 2360 1390 15,9 0 10 0,4 2490 1470 7,8 0<br />

15 0,6 1990 1170 16,8 0 15 0,6 2140 1260 8,3 0<br />

20 0,8 1450 860 17,1 0 20 0,8 1690 1000 8,6 0<br />

25 1,0 960 570 17,4 0 25 1,0 <strong>120</strong>0 710 8,9 0<br />

30 1,2 600 350 18,1 0 30 1,2 850 500 9,3 0<br />

35 1,4 260 150 18,5 0 35 1,4 550 320 9,6 0<br />

40 1,6 50 30 19,3 0 40 1,6 240 140 9,8 0<br />

45 1,8 0 0 19,5 0 45 1,8 0 0 9,9 0<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 3,40 Kg<br />

LOW NOISE<br />

®<br />

WEIGHT 3,40 Kg<br />

LOW NOISE<br />

The dimensions are in <strong>mm</strong>. ( 25,4 <strong>mm</strong>. = 1 inch )<br />

FAN DIAMETER<br />

Diametro Ventola<br />

For the Axial Fans exposed to the water, mounted with motor-up and blade-down, we reco<strong>mm</strong>end to require the<br />

2 holes for the water discharge on the blade hub. At the end of the fan description please write “2H”.<br />

Per Elettroventole esposte all’acqua, e montate con il motore sopra e la ventola sotto, si raccomanda di chiedere<br />

i 2 fori di drenaggio sul mozzo della ventola. Aggiungere alla fine della descrizione prodotto la sigla “2H”.<br />

Test Voltage: 26,0 VOLT DC<br />

SUCTION<br />

385 <strong>mm</strong>.<br />

15 inch<br />

F55-24L8205/HT-26S Suction-Aspirante<br />

BLOWING<br />

Soffiante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm