Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
12V<br />
DC<br />
Static<br />
Pressure<br />
Test Voltage: 26,0 VOLT DC<br />
<strong>mm</strong> Airflow Airflow Current Airflow Airflow Current <strong>mm</strong> Airflow Airflow Current Airflow Airflow Current<br />
inch inch<br />
H2O m3/h cfm/h Amp. m3/h cfm/h Amp . H2O m3/h cfm/h Amp. m3/h cfm/h Amp.<br />
0,0 0 1870 1100 9,4 1730 1020 8,9 0,0 0 1900 1<strong>120</strong> 4,7 1700 1000 4,3<br />
2,5 0,1 1680 990 9,5 1530 900 9,0 2,5 0,1 1600 940 4,7 1480 870 4,4<br />
5,0 0,2 1470 870 9,4 1350 800 9,0 5,0 0,2 1450 860 4,7 1290 760 4,4<br />
7,5 0,3 <strong>120</strong>0 710 9,3 1080 640 9,0 7,5 0,3 1270 750 4,7 1030 610 4,4<br />
10,0 0,4 890 530 9,1 820 480 9,0 10,0 0,4 1000 590 4,7 750 440 4,4<br />
12,5 0,5 520 310 9,1 610 360 9,0 12,5 0,5 680 400 4,7 520 310 4,4<br />
15,0 0,6 150 90 9,2 220 130 9,0 15,0 0,6 470 280 4,8 160 90 4,5<br />
17,5 0,7 0 0 9,3 0 0 9,5 17,5 0,7 <strong>120</strong> 70 4,9 0 0 4,7<br />
20,0 0,8 0 0 4,9<br />
WEIGHT 1,20 Kg<br />
LOW NOISE<br />
®<br />
F07P-12EL8002/HT-02S Suction - Aspirante<br />
F07P-12EL8002/HT-02B Blowing - Soffiante<br />
Test Voltage: 13,0 VOLT DC<br />
SUCTION<br />
Aspirante<br />
AXIAL FANS<br />
BLOWING<br />
Soffiante<br />
Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />
Airflow rate: 1 m3/h = 0,59 cfm<br />
FAN DIAMETER<br />
24V<br />
DC<br />
Pressure<br />
LOW NOISE<br />
The dimensions are in <strong>mm</strong>. ( 25,4 <strong>mm</strong>. = 1 inch )<br />
Diametro Ventola<br />
280 <strong>mm</strong>.<br />
11 inch<br />
F07P-24EL8002/HT-02S Suction - Aspirante<br />
F07P-24EL8002/HT-02B Blowing - Soffiante<br />
Static SUCTION<br />
BLOWING<br />
Aspirante Soffiante<br />
Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />
Airflow rate: 1 m3/h = 0,59 cfm<br />
WEIGHT 1,20 Kg<br />
For the Axial Fans exposed to the water, mounted with motor-up and blade-down, we reco<strong>mm</strong>end to require the<br />
2 holes for the water discharge on the blade hub. At the end of the fan description please write “2H”.<br />
Per Elettroventole esposte all’acqua, e montate con il motore sopra e la ventola sotto, si raccomanda di chiedere<br />
i 2 fori di drenaggio sul mozzo della ventola. Aggiungere alla fine della descrizione prodotto la sigla “2H”.