12V<br />

DC<br />

Static<br />

Pressure<br />

<strong>mm</strong> Airflow Airflow Current Airflow Airflow Current <strong>mm</strong> Airflow Airflow Current Airflow Airflow Current<br />

inch<br />

inch<br />

H2O m3/h cfm/h Amp. m3/h cfm/h Amp . H2O m3/h cfm/h Amp. m3/h cfm/h Amp.<br />

0 0 2850 1680 14,0 2860 1690 13,7 0 0 3010 1780 7,5 3060 1810 7,5<br />

5 0,2 2600 1530 15,0 2670 1580 14,8 5 0,2 2760 1630 8,1 2840 1680 7,8<br />

10 0,4 2340 1380 16,1 2420 1430 16,3 10 0,4 2520 1490 8,6 2580 1520 8,4<br />

15 0,6 2080 1230 17,0 2070 1220 17,6 15 0,6 2230 1320 9,0 2250 1330 9,0<br />

20 0,8 1630 960 17,6 1660 980 18,6 20 0,8 1900 1<strong>120</strong> 9,5 1830 1080 9,5<br />

25 1,0 1050 620 17,6 1240 730 19,3 25 1,0 1340 790 9,6 1460 860 9,9<br />

30 1,2 760 450 18,2 870 510 19,5 30 1,2 820 480 9,4 1100 650 10,2<br />

35 1,4 540 320 18,8 480 280 19,8 35 1,4 600 350 9,8 630 370 10,1<br />

40 1,6 320 190 19,5 220 130 20,5 40 1,6 380 220 10,1 380 220 10,2<br />

45 1,8 50 30 19,6 0 0 21,8 45 1,8 160 90 10,5 160 90 10,9<br />

50 2,0 0 0 21,0 50 2,0 0 0 10,9 0 0 11,5<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 2,40 Kg<br />

LOW NOISE<br />

®<br />

Test Voltage: 13,0 VOLT DC<br />

SUCTION<br />

AXIAL FANS<br />

F03-12L8201-03S Suction - Aspirante<br />

F03-12L8201-03B Blowing - Soffiante<br />

BLOWING<br />

24V<br />

DC<br />

Static<br />

Aspirante Soffiante<br />

Pressure<br />

Aspirante<br />

LOW NOISE<br />

The dimensions are in <strong>mm</strong>. ( 25,4 <strong>mm</strong>. = 1 inch )<br />

FAN DIAMETER<br />

Diametro Ventola<br />

SUCTION<br />

For the Axial Fans exposed to the water, mounted with motor-up and blade-down, we reco<strong>mm</strong>end to require the<br />

2 holes for the water discharge on the blade hub. At the end of the fan description please write “2H”.<br />

Per Elettroventole esposte all’acqua, e montate con il motore sopra e la ventola sotto, si raccomanda di chiedere<br />

i 2 fori di drenaggio sul mozzo della ventola. Aggiungere alla fine della descrizione prodotto la sigla “2H”.<br />

305 <strong>mm</strong>.<br />

12 inch<br />

F03-24L8201-03S Suction - Aspirante<br />

F03-24L8201-03B Blowing - Soffiante<br />

Test Voltage: 26,0 VOLT DC<br />

BLOWING<br />

Soffiante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 2,40 Kg