17.12.2012 Views

120 mm. - Kühler Rath KG

120 mm. - Kühler Rath KG

120 mm. - Kühler Rath KG

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

12V<br />

DC<br />

Static<br />

Pressure<br />

AXIAL FANS<br />

F36-12L8203-03S Suction - Aspirante<br />

F36-12L8203-03B Blowing - Soffiante<br />

Test Voltage: 13,0 VOLT DC<br />

SUCTION<br />

BLOWING<br />

FAN DIAMETER<br />

<strong>mm</strong> Airflow Airflow Current Airflow Airflow Current <strong>mm</strong> Airflow Airflow Current Airflow Airflow Current<br />

inch<br />

inch<br />

H2O m3/h cfm/h Amp. m3/h cfm/h Amp . H2O m3/h cfm/h Amp. m3/h cfm/h Amp.<br />

0 0 2590 1530 14,8 2620 1550 14,5 0 0 2580 1520 7,1 2620 1550 7,1<br />

5 0,2 2340 1380 15,5 2380 1400 15,4 5 0,2 2380 1400 7,6 2420 1430 7,6<br />

10 0,4 2090 1230 16,3 2060 1220 16,7 10 0,4 2130 1260 8,0 2090 1230 8,1<br />

15 0,6 1720 1010 16,7 1680 990 17,3 15 0,6 1770 1040 8,1 1730 1020 8,4<br />

20 0,8 1180 700 16,2 1350 800 18,2 20 0,8 1230 730 8,0 1370 810 8,6<br />

25 1,0 870 510 17,2 1040 610 18,7 25 1,0 910 540 8,2 1060 630 8,9<br />

30 1,2 620 370 17,7 710 420 18,6 30 1,2 670 400 8,5 740 440 8,9<br />

35 1,4 350 210 18,0 400 240 19,1 35 1,4 420 250 8,7 420 250 9,0<br />

40 1,6 <strong>120</strong> 70 18,3 130 80 20,0 40 1,6 170 100 9,0 180 110 9,5<br />

45 1,8 0 0 18,5 0 0 20,6 45 1,8 0 0 9,3 0 0 9,9<br />

24V<br />

DC<br />

Static<br />

WEIGHT 2,40 Kg<br />

LOW NOISE<br />

The dimensions are in <strong>mm</strong>. ( 25,4 <strong>mm</strong>. = 1 inch )<br />

Diametro Ventola<br />

SUCTION<br />

Aspirante Soffiante<br />

Pressure<br />

Aspirante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 2,40 Kg<br />

LOW NOISE<br />

®<br />

For the Axial Fans exposed to the water, mounted with motor-up and blade-down, we reco<strong>mm</strong>end to require the<br />

2 holes for the water discharge on the blade hub. At the end of the fan description please write “2H”.<br />

Per Elettroventole esposte all’acqua, e montate con il motore sopra e la ventola sotto, si raccomanda di chiedere<br />

i 2 fori di drenaggio sul mozzo della ventola. Aggiungere alla fine della descrizione prodotto la sigla “2H”.<br />

305 <strong>mm</strong>.<br />

12 inch<br />

F36-24L8203-03S Suction - Aspirante<br />

F36-24L8203-03B Blowing - Soffiante<br />

Test Voltage: 26,0 VOLT DC<br />

BLOWING<br />

Soffiante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!