12V<br />

DC<br />

Static<br />

Pressure<br />

<strong>mm</strong> Airflow Airflow Current Airflow Airflow Current <strong>mm</strong> Airflow Airflow Current Airflow Airflow Current<br />

inch<br />

inch<br />

H2O m3/h cfm/h Amp. m3/h cfm/h Amp . H2O m3/h cfm/h Amp. m3/h cfm/h Amp.<br />

0 0 2830 1670 16,3 2810 1660 16,1 0 0 2910 1720 8,9 2850 1680 8,5<br />

5 0,2 2590 1530 17,4 2600 1530 17,1 5 0,2 2700 1590 9,5 2640 1560 9,0<br />

10 0,4 2320 1370 18,3 2370 1400 18,2 10 0,4 2450 1450 10,0 2410 1420 9,6<br />

15 0,6 2030 <strong>120</strong>0 19,3 2020 1190 19,3 15 0,6 2180 1290 10,4 2100 1240 10,1<br />

20 0,8 1550 910 19,8 1440 850 20,5 20 0,8 1820 1070 10,7 1680 990 10,5<br />

25 1,0 1080 640 19,8 1080 640 20,9 25 1,0 1320 780 10,7 1170 690 11,0<br />

30 1,2 760 450 20,5 730 430 21,1 30 1,2 910 540 10,8 840 500 11,1<br />

35 1,4 500 300 21,0 420 250 21,2 35 1,4 680 400 11,1 520 310 11,1<br />

40 1,6 220 130 21,7 190 110 22,0 40 1,6 460 270 11,5 300 180 11,3<br />

45 1,8 30 20 22,1 20 10 23,4 45 1,8 230 140 11,8 110 60 11,9<br />

50 2,0 0 0 22,7 0 0 23,6 50 2,0 60 40 12,3 50 30 12,5<br />

55 2,2 55 2,2 0 0 12,5 0 0 12,6<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 2,40 Kg<br />

LOW NOISE<br />

®<br />

Test Voltage: 13,0 VOLT DC<br />

SUCTION<br />

AXIAL FANS<br />

F03-12I8201-03S Suction - Aspirante<br />

F03-12I8201-03B Blowing - Soffiante<br />

BLOWING<br />

24V<br />

DC<br />

Static<br />

Aspirante Soffiante<br />

Pressure<br />

Aspirante<br />

LOW NOISE<br />

The dimensions are in <strong>mm</strong>. ( 25,4 <strong>mm</strong>. = 1 inch )<br />

FAN DIAMETER<br />

Diametro Ventola<br />

SUCTION<br />

For the Axial Fans exposed to the water, mounted with motor-up and blade-down, we reco<strong>mm</strong>end to require the<br />

2 holes for the water discharge on the blade hub. At the end of the fan description please write “2H”.<br />

Per Elettroventole esposte all’acqua, e montate con il motore sopra e la ventola sotto, si raccomanda di chiedere<br />

i 2 fori di drenaggio sul mozzo della ventola. Aggiungere alla fine della descrizione prodotto la sigla “2H”.<br />

305 <strong>mm</strong>.<br />

12 inch<br />

F03-24I8201-03S Suction - Aspirante<br />

F03-24I8201-03B Blowing - Soffiante<br />

Test Voltage: 26,0 VOLT DC<br />

BLOWING<br />

Soffiante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 2,40 Kg