You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
12V<br />
DC<br />
AXIAL FANS<br />
F56-12L8205/HT-35S Suction-Aspirante<br />
Test Voltage: 13,0 VOLT DC<br />
Test Voltage: 26,0 VOLT DC<br />
Static SUCTION<br />
BLOWING<br />
Static<br />
SUCTION<br />
Pressure Aspirante Soffiante<br />
Pressure<br />
Aspirante<br />
<strong>mm</strong> Airflow Airflow Current Airflow Airflow Current <strong>mm</strong> Airflow Airflow Current Airflow Airflow Current<br />
inch inch<br />
H2O m3/h cfm/h Amp. m3/h cfm/h Amp . H2O m3/h cfm/h Amp. m3/h cfm/h Amp.<br />
24V<br />
DC<br />
0 0 3260 1920 15,4 0 0 0 3400 2010 8,3 0<br />
2,5 0,1 3050 1800 15,8 0 2,5 0,1 3230 1910 8,7 0<br />
5,0 0,2 2850 1680 16,5 0 5,0 0,2 3060 1810 9,1 0<br />
7,5 0,3 2630 1550 17,0 0 7,5 0,3 2850 1680 9,4 0<br />
10,0 0,4 2410 1420 17,6 0 10,0 0,4 2670 1580 9,8 0<br />
12,5 0,5 2140 1260 17,9 0 12,5 0,5 2470 1460 10,0 0<br />
15,0 0,6 1770 1040 17,8 0 15,0 0,6 2220 1310 10,2 0<br />
17,5 0,7 1430 840 18,5 0 17,5 0,7 1880 1110 10,2 0<br />
20,0 0,8 990 580 18,1 0 20,0 0,8 1530 900 10,3 0<br />
25,0 1,0 320 190 18,5 0 25,0 1,0 770 450 10,3 0<br />
30,0 1,2 40 20 19,1 0 30,0 1,2 180 110 10,5 0<br />
35,0 1,4 0 0 19,8 0 35,0 1,4 0 0 10,9 0<br />
Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />
Airflow rate: 1 m3/h = 0,59 cfm<br />
WEIGHT 3,40 Kg<br />
LOW NOISE<br />
�<br />
FAN DIAMETER<br />
Diametro Ventola<br />
WEIGHT 3,40 Kg<br />
LOW NOISE<br />
The dimensions are in <strong>mm</strong>. ( 25,4 <strong>mm</strong>. = 1 inch )<br />
For the Axial Fans exposed to the water, mounted with motor-up and blade-down, we reco<strong>mm</strong>end to require the<br />
2 holes for the water discharge on the blade hub. At the end of the fan description please write “2H”.<br />
Per Elettroventole esposte all’acqua, e montate con il motore sopra e la ventola sotto, si raccomanda di chiedere<br />
i 2 fori di drenaggio sul mozzo della ventola. Aggiungere alla fine della descrizione prodotto la sigla “2H”.<br />
385 <strong>mm</strong>.<br />
15 inch<br />
F56-24L8205/HT-35S Suction-Aspirante<br />
BLOWING<br />
Soffiante<br />
Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />
Airflow rate: 1 m3/h = 0,59 cfm