17.12.2012 Views

120 mm. - Kühler Rath KG

120 mm. - Kühler Rath KG

120 mm. - Kühler Rath KG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

12V<br />

DC<br />

Static<br />

Pressure<br />

<strong>mm</strong> Airflow Airflow Current Airflow Airflow Current <strong>mm</strong> Airflow Airflow Current Airflow Airflow Current<br />

inch<br />

inch<br />

H2O m3/h cfm/h Amp. m3/h cfm/h Amp . H2O m3/h cfm/h Amp. m3/h cfm/h Amp.<br />

0 0 2840 1680 16,5 0 0 0 2780 1640 7,6 0<br />

5 0,2 2660 1570 18,0 0 5 0,2 2610 1540 8,2 0<br />

10 0,4 2470 1460 19,5 0 10 0,4 2420 1430 8,8 0<br />

15 0,6 2260 1330 20,9 0 15 0,6 2210 1300 9,5 0<br />

20 0,8 1990 1170 22,2 0 20 0,8 1930 1140 10,1 0<br />

25 1,0 1570 930 22,8 0 25 1,0 1560 920 10,5 0<br />

30 1,2 1175 690 23,8 0 30 1,2 1130 670 10,7 0<br />

35 1,4 910 540 24,7 0 35 1,4 870 510 11,1 0<br />

40 1,6 690 410 25,7 0 40 1,6 670 400 11,7 0<br />

45 1,8 470 280 26,9 0 45 1,8 470 280 12,2 0<br />

50 2,0 260 150 28,0 0 50 2,0 280 170 12,8 0<br />

60 2,4 0 0 30,3 0 60 2,4 0 0 14,0<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 2,40 Kg<br />

LOW NOISE<br />

®<br />

Test Voltage: 13,0 VOLT DC<br />

SUCTION<br />

AXIAL FANS<br />

F03-12L8202/HT-16S Suction-Aspirante<br />

BLOWING<br />

24V<br />

DC<br />

Static<br />

Aspirante Soffiante<br />

Pressure<br />

Aspirante<br />

LOW NOISE<br />

The dimensions are in <strong>mm</strong>. ( 25,4 <strong>mm</strong>. = 1 inch )<br />

FAN DIAMETER<br />

Diametro Ventola<br />

SUCTION<br />

For the Axial Fans exposed to the water, mounted with motor-up and blade-down, we reco<strong>mm</strong>end to require the<br />

2 holes for the water discharge on the blade hub. At the end of the fan description please write “2H”.<br />

Per Elettroventole esposte all’acqua, e montate con il motore sopra e la ventola sotto, si raccomanda di chiedere<br />

i 2 fori di drenaggio sul mozzo della ventola. Aggiungere alla fine della descrizione prodotto la sigla “2H”.<br />

305 <strong>mm</strong>.<br />

12 inch<br />

F03-24L8202/HT-16S Suction-Aspirante<br />

Test Voltage: 26,0 VOLT DC<br />

BLOWING<br />

Soffiante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 2,40 Kg

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!