12V<br />

DC<br />

Test Voltage: 13,0 VOLT DC<br />

AXIAL FANS<br />

F55-12L8205/HT-08S Suction-Aspirante<br />

F55-12L8205/HT-08B Blowing-Soffiante<br />

<strong>mm</strong> Airflow Airflow Current Airflow Airflow Current <strong>mm</strong> Airflow Airflow Current Airflow Airflow Current<br />

inch inch<br />

H2O m3/h cfm/h Amp. m3/h cfm/h Amp . H2O m3/h cfm/h Amp. m3/h cfm/h Amp.<br />

0 0 3710 2190 17,1 3870 2280 17,0 0 0 3880 2290 8,7 3980 2350 8,5<br />

2,5 0,1 3440 2030 17,3 3630 2140 17,4 2,5 0,1 3660 2160 9,0 3760 2220 8,8<br />

5,0 0,2 3210 1890 17,9 3370 1990 17,8 5,0 0,2 3450 2040 9,2 3540 2090 9,1<br />

7,5 0,3 2920 1720 18,2 3040 1790 18,1 7,5 0,3 3180 1880 9,4 3280 1940 9,3<br />

10,0 0,4 2650 1560 18,5 2640 1560 18,5 10,0 0,4 2910 1720 9,5 2920 1720 9,5<br />

12,5 0,5 2320 1370 18,4 2180 1290 18,5 12,5 0,5 2630 1550 9,6 2520 1490 9,6<br />

15,0 0,6 1860 1100 18,1 1450 860 18,2 15,0 0,6 2260 1330 9,6 1810 1070 9,6<br />

17,5 0,7 1240 730 17,7 930 550 18,0 17,5 0,7 1800 1060 9,5 1300 770 9,5<br />

20,0 0,8 710 420 17,7 420 250 18,0 20,0 0,8 <strong>120</strong>0 710 9,2 750 440 9,2<br />

22,5 0,9 200 <strong>120</strong> 18,6 110 60 18,8 22,5 0,9 730 430 9,4 340 200 9,5<br />

25,0 1,0 40 20 19,3 50 30 19,1 25,0 1,0 250 150 9,8 70 40 9,8<br />

30,0 1,2 0 0 19,5 0 0 19,4 30,0 1,2 0 0 10,0 0 0 9,9<br />

24V<br />

DC<br />

Static SUCTION<br />

BLOWING<br />

Static<br />

Pressure Aspirante Soffiante<br />

Pressure<br />

Aspirante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm<br />

WEIGHT 3,40 Kg<br />

LOW NOISE<br />

®<br />

WEIGHT 3,40 Kg<br />

LOW NOISE<br />

The dimensions are in <strong>mm</strong>. ( 25,4 <strong>mm</strong>. = 1 inch )<br />

FAN DIAMETER<br />

Diametro Ventola<br />

For the Axial Fans exposed to the water, mounted with motor-up and blade-down, we reco<strong>mm</strong>end to require the<br />

2 holes for the water discharge on the blade hub. At the end of the fan description please write “2H”.<br />

Per Elettroventole esposte all’acqua, e montate con il motore sopra e la ventola sotto, si raccomanda di chiedere<br />

i 2 fori di drenaggio sul mozzo della ventola. Aggiungere alla fine della descrizione prodotto la sigla “2H”.<br />

F55-24L8205/HT-08B Blowing-Soffiante<br />

Test Voltage: 26,0 VOLT DC<br />

SUCTION<br />

385 <strong>mm</strong>.<br />

15 inch<br />

F55-24L8205/HT-08S Suction-Aspirante<br />

BLOWING<br />

Soffiante<br />

Static Pressure: 1 <strong>mm</strong> H2O = 0,04 inch H2O 1 <strong>mm</strong> H2O = 9,8 Pa<br />

Airflow rate: 1 m3/h = 0,59 cfm