Specification text Order No. b<br />
<strong>DORMA</strong> TL-S <strong>TMS</strong><br />
Control and interface PCB for installation in TL-G 3xx/5xx<br />
<strong>TMS</strong> or TL-G 3xx/5xx.<br />
Designed for connection of max. four TV 1xx DCW ® electrical<br />
door locking elements and ST 3x DCW ® key switches,<br />
DCW ® I/O modules, SVP-S 2x DCW ® plus further DCW ® bus<br />
devices. Suitable for connection to a hazard alert system<br />
and/or fire alarm system or smoke detector (RM) for emergency<br />
unlocking via floating contact.<br />
DCW ® system bus with automatic device detection and default<br />
parameterisation of all DCW ® system components; customerspecific<br />
requirements programmable via parameterisation<br />
keypad AT 01 DCW ® or <strong>TMS</strong>-Soft parameterisation software.<br />
Integrated short-time, long-time and permanent unlocking via<br />
key-operated momentary contact device with programmable<br />
with parameterisable key operating times and functions.<br />
Following power failure, immediate locking action.<br />
Integrated timer with two time zones per day, adjustable via<br />
<strong>TMS</strong>-Soft. Integrated access control with AT 01 DCW ® pin<br />
code keypad.<br />
Automatic re-locking following authorised unlocking, effected<br />
after between 3 and 180 seconds via short-time timer,<br />
or 3–120 minutes via long-time timer, programmable with<br />
parameterisation keypad AT 01 DCW ® or <strong>TMS</strong>-Soft parameterisation<br />
software.<br />
Door-open monitoring begins on expiry of the time set in the<br />
timers.<br />
Door-open alarm signal can be delayed from 5 to 180 seconds.<br />
Programmable duration of pre-alarm and main alarm.<br />
Programmable premature re-locking via door contact after<br />
door closure with automatic re-locking mode activated.<br />
Differentiated audible alarm for door-open time exceeded<br />
(pre- and/or main alarm), sabotage/tamper attempt, emergency-open<br />
and fire alarm signals, with local alarm indication<br />
and automatic local alarm cancellation after 180 seconds.<br />
Integrated differential bus cables (monitored for short<br />
circuit/interruption).<br />
Functionality of the integrated key switch and also the<br />
external key switch ST 3x DCW ® adjustable and definable.<br />
Prepared for connection via LON and RS 232 interface to<br />
BUS or conventional systems such as integrated building<br />
management controls and additional control and signalling<br />
devices. Disabling inputs and logic function gating plus<br />
control and actuation of various systems (e.g.: automatic<br />
operators, access control system, etc.) via up to four<br />
DCW ® I/O modules.<br />
Power supply: 24V DC, +/– 10 %<br />
Current input, max.: approx. 65 mA<br />
approx. 90 mA in alarm mode<br />
Contact rating: 24V DC, 0.5 A inductive<br />
24 V DC, 1.0 A ohmic 56330100 b TL-S <strong>TMS</strong><br />
<strong>DORMA</strong> TL-S DCW`<br />
Terminal interface board for installation in TL-G 3xx/5xx and<br />
connection to control types TL <strong>TMS</strong> or RZ <strong>TMS</strong> via <strong>DORMA</strong><br />
system bus DCW ® . Up to 4 TL-S DCW ® boards can be<br />
connected via the system bus. Parameters such as adjustable<br />
and restrictable functions of the integrated key switch,<br />
the TL-S <strong>TMS</strong> or RZ <strong>TMS</strong> are automatically transferred.<br />
Power supply: 24V DC, +/– 10 %<br />
via DCW ® system bus<br />
Current input, max.: approx. 65 mA<br />
approx. 85 mA in alarm mode 56330200 b TL-S DCW`<br />
11