Specification text Order No. b<br />
<strong>DORMA</strong> RZ <strong>TMS</strong><br />
Emergency exit control PCB in plastics enclosure, IP 54, with<br />
cover contacts including power supply PCB type <strong>DORMA</strong> NT-S<br />
24-1.5, I/O module and DCW ® branching module. Prepared<br />
for installation of motor lock control type <strong>DORMA</strong> SVP-S22 or<br />
SVP-S22 DCW ® and further I/O modules.<br />
Designed for the connection of up to 4 TL-G 3xx/5xx DCW ® or<br />
TL-UP S55, door locking elements TV 1xx DCW ® , 2xx DCW ®<br />
or 5xx DCW ® , and key switches type ST 3x DCW ® as well as<br />
further DCW ® bus devices. Suitable for connection of a hazard<br />
warning alarm and/or fire alarm and control unit or RM smoke<br />
detector for emergency unlocking via floating contact or<br />
I/O module.<br />
DCW ® system bus with device auto-identification; default<br />
parameterisation of all DCW ® system components and<br />
customer-specific requirements programmable via parameterising<br />
keyboard AT 01 DCW ® or parameterising software<br />
<strong>TMS</strong>-Soft.<br />
Integrated programmable short-time or long-time and<br />
permanent unlocking via key-operated momentary contact<br />
device (e.g. TL-G 3xx/5xx DCW ® , TL-UP S55 or ST key switch)<br />
with parameterisable key actuation times and functions.<br />
Instant re-locking on power failure. Automatic re-locking<br />
function after authorised unlocking programmable for 3–180<br />
seconds via short timer or 3–120 minutes via long timer with<br />
parameterisation keyboard AT 01 DCW ® or parameterisation<br />
software <strong>TMS</strong>-Soft. After timer expiry, door-open monitoring<br />
mode begins. Door open alarm delay adjustable 5–180 seconds.<br />
Duration of pre-alarm and main alarm programmable. After<br />
door closure with automatic re-locking mode active, premature<br />
re-locking can be programmed for activation by door contact.<br />
Differentiated audible alarm to indicate excedence of door<br />
open time (pre-alarm and/or main alarm), tamper attempt,<br />
abuse attempt, emergency open and fire alarm with local<br />
alarm; with automatic local alarm shutdown after 180 seconds<br />
at door terminal. Integrated differential bus cables (monitored<br />
for short circuit/cable break). Functions of the external keyoperated<br />
momentary contact device, e.g. TL-G 3xx/5xx DCW ® ,<br />
TL-UP S55 or ST32 DCW ® can be adjusted and restricted as<br />
required.<br />
<strong>DORMA</strong> DCW ® I/O module for connection of products with<br />
conventional cabling to the <strong>DORMA</strong> DCW ® system bus,<br />
e.g.: connection of a TG/TE monitoring and control unit, BL<br />
flashing lamp, AS external alarm siren, or access control<br />
system by others. Four opto-coupler inputs for transmission of<br />
external signals and control commands, e.g. disabling input<br />
for intruder alarm system (floating or non-floating) and four<br />
floating outputs for activation of external components or<br />
for output of signals. Up to four DCW ® I/O modules per <strong>TMS</strong><br />
possible.<br />
Addresses pre-parameterised for various requirements.<br />
Individual requirements can be accommodated by programming<br />
using the parameterisation keyboard AT 01 DCW ® or parameterisation<br />
software <strong>TMS</strong>-Soft (e.g. switch-on delay, monoflop<br />
function, flashing mode, logic/gating operations, etc.).<br />
Power supply: 230V AC, +/– 10 %<br />
Dimensions (W x H x D) approx.: 300 x 230 x 85 mm 56331100 b RZ <strong>TMS</strong><br />
NT-S 24-1.5<br />