NH slimline fuse-switch<br />

disconnector modules<br />

(100/185 mm)<br />

For NH slimline fuse-switch disconnectors,<br />

sizes 00 to 3.<br />

Colour:<br />

RAL 7035<br />

For NH slimline fuseswitch<br />

disconnectors Description<br />

SV 9346.020<br />

SV 9346.030<br />

SV 9346.065<br />

SV 9346.040<br />

SV 9346.050<br />

SV 9346.110/.115<br />

SV 9346.210/.215<br />

SV 9346.310/.315<br />

1) 1 WU 250 mm<br />

2) 1 U 150 mm<br />

Rittal <strong>Innovations</strong> <strong>2012</strong><br />

100 mm module,<br />

3-pole,<br />

max. 3 x NH size 00<br />

100 mm module,<br />

3-pole,<br />

max. 6 x NH size 00<br />

100 mm module,<br />

3-pole,<br />

max. 10 x NH size 00<br />

185 mm module,<br />

3-pole,<br />

max. 8 x NH size 00/<br />

4 x NH size 1, 2, 3<br />

185 mm module,<br />

3-pole,<br />

max. 12 x NH size 00/<br />

6 x NH size 1, 2, 3<br />

Meter mounting board module<br />

� Open module for internal measurements<br />

� Clearance depth available for meter installation<br />

170 mm<br />

Colour:<br />

RAL 7035<br />

ISV distribution enclosures<br />

Installation modules<br />

Note:<br />

− Busbars are not included with the supply<br />

− In order to ensure problem-free cable connection,<br />

a contact hazard protection module<br />

(see page 82) or an N/PE busbar module<br />

(see page 84) must be installed above or below<br />

the NH slimline fuse-switch disconnector<br />

modules<br />

Size Packs<br />

Width unit (WU) of<br />

1) Height unit (U) 2)<br />

Model No.<br />

SV<br />

1 250 mm 3 450 mm 1 9666.570<br />

2 500 mm 3 450 mm 1 9666.580<br />

3 750 mm 3 450 mm 1 9666.583<br />

2 500 mm 5 750 mm 1 9666.550<br />

3 750 mm 5 750 mm 1 9666.560<br />

Note:<br />

− The meter mounting board module does not<br />

comply with meter mounting board standard<br />

DIN 43 870/VDE 0603 and does not meet the<br />

conditions for total insulation. Use in unmetered<br />

areas only by arrangement with the local<br />

electricity supply company<br />

− 1 contact hazard protection module or support<br />

rail module with 1 WU and at least 1 U is<br />

required both above and below the module,<br />

see page 82<br />

Description<br />

Size<br />

Width unit (WU)<br />

Packs<br />

of<br />

Model No.<br />

SV<br />

1) Height unit (U) 2)<br />

Meter mounting board module 1 250 mm 3 450 mm 1 9666.640<br />

1) 1 WU 250 mm<br />

2) 1 U 150 mm<br />

85