External, internal or partial<br />
internal mounting<br />
This makes optimum allowance<br />
for the available space conditions.<br />
The enclosure surface<br />
containing the cut-out for partial<br />
or full internal mounting is stabilised<br />
by the divided internal<br />
case construction. Special internal<br />
or external mounting kits are<br />
not required.<br />
Cut your costs<br />
All rotary current units are<br />
designed for a voltage range of<br />
400/460 V and a frequency<br />
range of 50/60 Hz without rewiring.<br />
No need for expensive additional<br />
transformers.<br />
The design and arrangement of<br />
the assemblies and membranes<br />
of the TopTherm cooling units<br />
have been optimised for maximum<br />
performance.<br />
Flexible performance<br />
Just 5 mounting cut-outs for<br />
8 different output categories<br />
in 35 design variants provide<br />
investment security and facilitate<br />
easy adaptation of the cooling<br />
output to the ambient conditions<br />
and the installed heat loss.<br />
<strong>Rittal</strong> platform strategy<br />
TopTherm air/air and air/water<br />
heat exchangers are also compatible<br />
with the mounting cutouts<br />
of wall-mounted cooling<br />
units.<br />
<strong>Rittal</strong> <strong>System</strong> <strong>Climate</strong> <strong>Control</strong><br />
<strong>Rittal</strong> TopTherm wall-<br />
mounted cooling units:<br />
Top design and top perform-<br />
ance with a host of assem-<br />
bly benefits. The <strong>Rittal</strong><br />
platform strategy with system-wide mounting cut-outs to fit<br />
cooling units and air/air heat exchangers allows easy adapta-<br />
tion to the required cooling output, even retrospectively.<br />
Benefits<br />
in brief !<br />
● Wide output range<br />
from 225 to 4000 W<br />
● Extensive control and<br />
monitoring features,<br />
even with the basic<br />
version<br />
● Three-phase cooling<br />
units support multiple<br />
voltages as standard<br />
● Uniform, performance-related,systemwide<br />
mounting cutouts<br />
● To match TopTherm<br />
air/air heat exchangers.<br />
Important<br />
● Air inlet and outlet<br />
openings in the internal<br />
and external circuit<br />
must not be obstructed<br />
by electrical installations.<br />
General remarks<br />
see page 33<br />
Calculation formulae<br />
see page 27<br />
or on our website:<br />
www.rittal.com<br />
Quick-change frame<br />
Together with the seal, the lower<br />
part of the two-part quickchange<br />
frame is screw-fastened<br />
to the enclosure. This makes it<br />
possible to mount the connectorready<br />
cooling unit onto the<br />
enclosure and remove it from the<br />
outside, using quick-release fasteners.<br />
During servicing work, this<br />
means shorter assembly times<br />
and hence minimised downtime.<br />
What is more, the quickchange<br />
frame offers effective<br />
protection against the ingress of<br />
oil into the enclosure in oily<br />
atmospheres, thanks to its integral<br />
drainage trough.<br />
1 Roof plate<br />
2 Quick-change frame,<br />
base part<br />
3 Quick-change frame,<br />
top part<br />
Cooling units<br />
Benefits<br />
<strong>Rittal</strong> TopTherm roof-<br />
mounted cooling units:<br />
Top design and top perform-<br />
ance with a host of assem-<br />
bly benefits and sophisti-<br />
cated air routing. The system-wide mounting cut-outs may<br />
also be used for the new roof-mounted fans for TS. Superb<br />
performance plus cost-cutting design.<br />
3<br />
2<br />
1<br />
Roof plates<br />
There are roof plates preequipped<br />
with a mounting cutout<br />
available to fit all standard<br />
enclosure dimensions and cooling<br />
unit output categories. Manual<br />
machining of the mounting<br />
cutouts has been eliminated<br />
altogether.<br />
Benefits<br />
in brief !<br />
● Wide output range<br />
from 500 to 4000 W<br />
● Extensive control and<br />
monitoring features,<br />
even with the basic<br />
version<br />
● Rotary current units<br />
support multiple voltages<br />
as standard<br />
● Uniform, performance-related,systemwide<br />
mounting cutouts<br />
● Targeted, individual<br />
air routing<br />
Important<br />
● Avoid overloading the<br />
roof plate by using<br />
stays (with TS 8 system<br />
accessories)<br />
General remarks<br />
see page 33<br />
Calculation formulae<br />
see page 27<br />
or on our website:<br />
www.rittal.com<br />