Emergency<br />

water supply<br />

Free<br />

cooling<br />

Heat use<br />

<strong>Rittal</strong> <strong>System</strong> <strong>Climate</strong> <strong>Control</strong><br />

Water/water heat<br />

exchanger<br />

LCP Extend<br />

Recooling system<br />

<strong>Control</strong><br />

Distribution<br />

PCS Power Cooling<br />

<strong>System</strong>s<br />

Direct cooling of electronic<br />

components (CPUs, power<br />

packs, hard disk drives etc.) in<br />

blade servers and other highperformance<br />

systems via a<br />

cooling circuit distributor.<br />

LCP Standard/LCP Plus<br />

Bayable with TS 8 server racks<br />

As the height and depth are<br />

identical, it may be bayed either<br />

in the middle of an enclosure<br />

suite or at the end, for added<br />

assembly and servicefriendliness.<br />

Installation while operational<br />

Air/water heat exchanger<br />

(10 kW) to support climate control<br />

of the room. For <strong>Rittal</strong> racks,<br />

the relevant door is preconfigured<br />

in the factory and<br />

exchanged on site.<br />

Liquid cooling systems<br />

Applications<br />

Modular climate control concepts <strong>–</strong> to your specific require-<br />

ments!<br />

<strong>Rittal</strong> solves the problem of climate control for high heat<br />

losses per rack with liquid cooling components. Extremely<br />

high heat loads are dissipated from the enclosures, IT and<br />

server racks via air/water heat exchangers.<br />

Additionally, data centres may be extended in a temperature-<br />

neutral way.<br />

2<br />

2<br />

1<br />

H<br />

Up to 40 kW useful cooling<br />

output<br />

The useful cooling output is<br />

achieved with a modular configuration<br />

(1 <strong>–</strong> 3 modules) or with<br />

the complete LCP Plus systems.<br />

Active condensate management<br />

supports inlet temperatures<br />

from +6°C to +20°C.<br />

Suitable for use on any<br />

surface<br />

The stand-alone unit may be fitted<br />

onto any suitably sized rear<br />

door (including other brands).<br />

1<br />

2<br />

DCP Direct<br />

Cooling Package<br />

The liquid-cooled partial<br />

mounting plate for direct cooling<br />

of frequency converters<br />

and other performance electronics.<br />

Air/water heat<br />

exchanger<br />

Dissipates high heat losses<br />

from the enclosure.<br />

Safe insertion,<br />

simple assembly<br />

The separation of cooling and<br />

rack prevents water from penetrating<br />

the server rack. A recooling<br />

system supplies the required<br />

cooling fluid.<br />

Water connection variants<br />

Water connection either at the<br />

bottom or top. Connection to the<br />

existing cooling circuit (optionally<br />

via water/water heat<br />

exchanger) or to recooling systems.<br />