Emergency<br />
water supply<br />
Free<br />
cooling<br />
Heat use<br />
<strong>Rittal</strong> <strong>System</strong> <strong>Climate</strong> <strong>Control</strong><br />
Water/water heat<br />
exchanger<br />
LCP Extend<br />
Recooling system<br />
<strong>Control</strong><br />
Distribution<br />
PCS Power Cooling<br />
<strong>System</strong>s<br />
Direct cooling of electronic<br />
components (CPUs, power<br />
packs, hard disk drives etc.) in<br />
blade servers and other highperformance<br />
systems via a<br />
cooling circuit distributor.<br />
LCP Standard/LCP Plus<br />
Bayable with TS 8 server racks<br />
As the height and depth are<br />
identical, it may be bayed either<br />
in the middle of an enclosure<br />
suite or at the end, for added<br />
assembly and servicefriendliness.<br />
Installation while operational<br />
Air/water heat exchanger<br />
(10 kW) to support climate control<br />
of the room. For <strong>Rittal</strong> racks,<br />
the relevant door is preconfigured<br />
in the factory and<br />
exchanged on site.<br />
Liquid cooling systems<br />
Applications<br />
Modular climate control concepts <strong>–</strong> to your specific require-<br />
ments!<br />
<strong>Rittal</strong> solves the problem of climate control for high heat<br />
losses per rack with liquid cooling components. Extremely<br />
high heat loads are dissipated from the enclosures, IT and<br />
server racks via air/water heat exchangers.<br />
Additionally, data centres may be extended in a temperature-<br />
neutral way.<br />
2<br />
2<br />
1<br />
H<br />
Up to 40 kW useful cooling<br />
output<br />
The useful cooling output is<br />
achieved with a modular configuration<br />
(1 <strong>–</strong> 3 modules) or with<br />
the complete LCP Plus systems.<br />
Active condensate management<br />
supports inlet temperatures<br />
from +6°C to +20°C.<br />
Suitable for use on any<br />
surface<br />
The stand-alone unit may be fitted<br />
onto any suitably sized rear<br />
door (including other brands).<br />
1<br />
2<br />
DCP Direct<br />
Cooling Package<br />
The liquid-cooled partial<br />
mounting plate for direct cooling<br />
of frequency converters<br />
and other performance electronics.<br />
Air/water heat<br />
exchanger<br />
Dissipates high heat losses<br />
from the enclosure.<br />
Safe insertion,<br />
simple assembly<br />
The separation of cooling and<br />
rack prevents water from penetrating<br />
the server rack. A recooling<br />
system supplies the required<br />
cooling fluid.<br />
Water connection variants<br />
Water connection either at the<br />
bottom or top. Connection to the<br />
existing cooling circuit (optionally<br />
via water/water heat<br />
exchanger) or to recooling systems.<br />