Modular PE terminals<br />

Identical profiles from 2.5 to 10 mm² with uni<strong>for</strong>m<br />

end <strong>and</strong> partition plates. An unsurpassed<br />

combination of many advantages!<br />

Their small size compared to the respective rated<br />

cross-section makes the modular terminals with<br />

the compact design very popular.<br />

In hazardous area applications, the installation instructions<br />

<strong>and</strong> the rated data specifications <strong>for</strong> accessories given in the<br />

technical appendix must be followed.<br />

Width/Length/height with TS35x7.5 mm<br />

max. cond. cross-section mm²<br />

Max. clamping range mm²<br />

Technical data<br />

Rated data<br />

Rated cross-section mm²<br />

Rated voltage to adjacent terminal V<br />

Rated impulse withst<strong>and</strong> voltage to adjacent terminal kV<br />

Short-time withst<strong>and</strong> current<br />

Pollution severity<br />

Gauge to IEC 60947-1 / UL94 Flammability class<br />

Approvals<br />

Clamped conductors (H05V/H07V)<br />

solid / str<strong>and</strong>ed mm²<br />

flexible / Str<strong>and</strong>ed wire with end ferrules mm²<br />

Tightening torque range (clamping screw)<br />

Tightening torque range (fixing screw)<br />

Stripping length / Blade size mm/-<br />

Note<br />

Ordering data<br />

Version<br />

Note<br />

Accessories<br />

End plate / partition<br />

End bracket<br />

Screwdriver<br />

green/yellow Wemid<br />

Dark beige Wemid<br />

Dark beige Wemid<br />

Dark beige Wemid<br />

Marking <strong>systems</strong><br />

Marking tags<br />

For detailed in<strong>for</strong>mation of the further accessories <strong>and</strong><br />

applications, please see our terminal catalogue<br />

102<br />

St<strong>and</strong>ard<br />

WPE 16 16 mm²<br />

11.9 x 56 x 63<br />

25<br />

1.5...25<br />

IEC 60947-7-2 Ex e II T II 2 G D<br />

IEC UL CSA EN 60079-7<br />

16<br />

1,000<br />

8<br />

AWG 14...4 AWG 14...6 16<br />

1920 A (16 mm²)<br />

3<br />

B7 / V-0<br />

? r u # i ~ x a<br />

Rated connection<br />

1.5...16 / 1.5...25<br />

1.5...25 / 1.5...16<br />

2.0...4.0 Nm (M 5)<br />

3.0...4.0 Nm<br />

16 / 1.0 x 5.5 mm<br />

Further connection<br />

For 25mm², the TS 35x15 (steel, 1.5mm thick) should be used. Conductor<br />

connection H07V-..16 <strong>and</strong> AWG 6 with tightening torque of 2.0-2.4 Nm.<br />

Type Qty Order No.<br />

WPE 16 50 1010400000<br />

Type Width Qty Order No.<br />

WEW 35/1 12 mm 50 1059000000<br />

SD 1.0x5.5x150 1 9008350000<br />

WQB-PEN 16 10 1060200000<br />

DEK 5/5 / WS 12/6,5<br />

Rail support <strong>for</strong> insulated installation of terminal rail „SH 2“ order no.<br />

0494920000 (10 pcs)<br />

PE<br />

WPE 35 35 mm²<br />

16 x 56 x 63<br />

50<br />

2.5...50<br />

IEC 60947-7-2 Ex e II T II 2 G D<br />

IEC UL CSA EN 60079-7<br />

35<br />

800<br />

8<br />

AWG 12...1 AWG 12...2 35<br />

4200 A (35 mm²)<br />

3<br />

B8 / V-0<br />

? r u # i ~ x a<br />

Rated connection<br />

2.5...16 / 2.5...50<br />

2.5...35 / 2.5...35<br />

4.0...5.0 Nm (M 6)<br />

1.2...2.4 Nm<br />

18 / 6.5 x 1.2 mm<br />

Further connection<br />

The torque is 4.5Nm <strong>for</strong> 16-50 mm² <strong>and</strong> AWG 6-2/7 str<strong>and</strong>ed wires. Use TS 35x15<br />

(1.5 mm thick) <strong>for</strong> 25mm² wires <strong>and</strong> TS 35x15(2.3mm thick) <strong>for</strong> 35mm²/50mm².<br />

Type Qty Order No.<br />

WPE 35 25 1010500000<br />

Type Width Qty Order No.<br />

WEW 35/1 12 mm 50 1059000000<br />

SD 1.2x6.5x150 1 9009010000<br />

WQB-PEN 35 10 1060100000<br />

DEK 5/5 / WS 12/6,5<br />

Rail support <strong>for</strong> insulated installation of terminal rail „SH 2“ order no.<br />

0494920000 (10 pcs)<br />

PE