28.01.2013 Views

Components and solutions for photovoltaic systems - Weidmüller

Components and solutions for photovoltaic systems - Weidmüller

Components and solutions for photovoltaic systems - Weidmüller

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Switch-mode power supplies INSTAPOWER<br />

connectPower single-phase<br />

Technical data<br />

Input<br />

Input voltage<br />

Input current<br />

Input frequency, max.<br />

making current limit<br />

Input fuse<br />

Surge protection<br />

Output<br />

Output voltage<br />

Output current<br />

Output power<br />

Max. residual ripple<br />

Overload protection<br />

Surge protection<br />

Mains failure bridge-over time<br />

Control at 10...100 % load<br />

Max. capacitance at output<br />

Insulation coordination (EN 50 178)<br />

electrical isolation, output-earth<br />

electrical isolation, input-earth<br />

electrical isolation, input-output<br />

electrical isolation, I/O rail<br />

General data<br />

Ambient temperature<br />

Storage temperature<br />

Degree of efficiency at max. load<br />

St<strong>and</strong>ards<br />

Approvals<br />

EMC st<strong>and</strong>ards<br />

Dimensions<br />

Clamping range (nominal / min. / max.) mm²<br />

Length x width x height mm<br />

Note<br />

Ordering data<br />

Connection system<br />

Note<br />

Accessories<br />

124<br />

Screw connection<br />

CP SNT 24 W 24 V 1 A<br />

L<br />

FUSE<br />

N −<br />

85...265 V AC, 120...300 V DC<br />

460 mA @ 115 V AC; 250 mA @ 230 V AC<br />

50/ 60 Hz<br />

Thermistor<br />

2 A time-lag fuse (internal)<br />

Varistor<br />

24 V DC<br />

1 A<br />

24 W<br />

< 2 %<br />

Surge current / thermal cut-out<br />

Varistor<br />

35 ms @ 115 V AC / 160 ms @ 230 V AC<br />

0,5 %<br />

8000 µF<br />

0.5 kV<br />

1.5 kV<br />

3 kV<br />

4 kV<br />

-20 °C...+50 °C<br />

-40 °C...+85 °C<br />

78 %<br />

EN 50178, EN 60950, IEC950<br />

UL508; CSA; Cl. I Div. 2; GOSTME25; CE; Class2<br />

EN 61000-6 /-2, -3<br />

Input/Output<br />

4 / 0.08 / 4<br />

62.5 / 52 / 90.5<br />

Derating loss: 33 % @ 60 °C<br />

Type Qty. Order No.<br />

CP SNT 24 W 24 V 1 A 1 9928890024<br />

+<br />

CP SNT 24 W 12 V 1.5 A<br />

L<br />

FUSE<br />

N −<br />

85...265 V AC, 120...300 V DC<br />

460 mA @ 115 V AC; 250 mA @ 230 V AC<br />

50/ 60 Hz<br />

Thermistor<br />

2 A time-lag fuse (internal)<br />

Varistor<br />

12 V DC<br />

1.5 A<br />

18 W<br />

< 2 %<br />

Surge current / thermal cut-out<br />

Varistor<br />

35 ms @ 115 V AC / 160 ms @ 230 V AC<br />

0,5 %<br />

8000 µF<br />

0.5 kV<br />

1.5 kV<br />

3 kV<br />

4 kV<br />

-20 °C...+50 °C<br />

-40 °C...+85 °C<br />

78 %<br />

EN 50178, EN 60950, IEC950<br />

CSA; GOSTME25; CE<br />

EN 61000-6 /-2, -3<br />

Input/Output<br />

4 / 0.08 / 4<br />

62.5 / 52 / 90.5<br />

Derating loss: 33 % @ 60 °C<br />

Type Qty. Order No.<br />

CP SNT 24 W 12 V 1,5 A 1 9928890012<br />

+

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!