Surge protection <strong>for</strong> <strong>photovoltaic</strong> <strong>systems</strong><br />

Surge protection on the energy supply side<br />

Lines can be charged with high currents <strong>and</strong> voltages following<br />

a lighting strike. This can lead to permanent damage <strong>and</strong> loss<br />

of the <strong>photovoltaic</strong> system. The use of lightning arresters <strong>and</strong><br />

surge protection devices results in a higher system availability<br />

Single-phase<br />

Three-phase<br />

TN-S / TT / IT<br />

TN-C<br />

In large-scale <strong>systems</strong>, the house shown<br />

relates to the inverter housing in the field.<br />

TN-S TT IT<br />

TN-C<br />

External lightning protection<br />

available<br />

then an internal lightning protector is required (Class I)<br />

Can be used with higher<br />

requirements in terms of<br />

availability <strong>and</strong><br />

in public facilities<br />

(Lightning protection level (LPL) I + II)<br />

PU I 1+1 LCF 280V/30KA<br />

Page 68<br />

PU I 3+1 LCF 280V/30KA<br />

Page 68<br />

PU I 3 LCF 280V/30KA<br />

Page 69<br />

* leakage current free versions <strong>for</strong> installation in front of the meter can be found in TK 4.4<br />

60<br />

<strong>and</strong> better profit. <strong>Weidmüller</strong> offers a complete range <strong>for</strong><br />

protection in accordance with IEC 60364-7-712 <strong>for</strong> the energy<br />

input <strong>for</strong> both roof-mounted <strong>systems</strong> <strong>and</strong> large-scale <strong>systems</strong>.<br />

Can be used <strong>for</strong><br />

domestic installation<br />

<strong>and</strong><br />

st<strong>and</strong>ard plants<br />

(Lightning protection level (LPL) III + IV)<br />

PU I 1+1 280V/12,5KA *<br />

Page 65<br />

PU I 3+1 280V/12,5KA *<br />

Page 64<br />

PU I 3 280V/12,5KA *<br />

Page 65<br />

No external lightning protection<br />

available<br />

then an overvoltage protection is sufficient (Class II)<br />

PU II 1+1 280V/40kA<br />

Page 66<br />

PU II 3+1 280V/40kA<br />

Page 66<br />

PU II 3 280V/40KA<br />

Page 67<br />

Ready-made st<strong>and</strong>ard <strong>solutions</strong><br />

<strong>Weidmüller</strong> offers an extensive range of pre-wired combiner boxes with surge<br />

protection devices <strong>for</strong> the AC side in 1- <strong>and</strong> 3-phase applications.<br />

The complete overview of our st<strong>and</strong>ard <strong>solutions</strong> can be found on pages 52 to 55.