DC surge protection<br />
in accordance with UTE<br />
Surge protection <strong>for</strong> <strong>photovoltaic</strong> applications,<br />
e.g. in France<br />
• Tested by UTE C 61-740-51 <strong>and</strong> the<br />
prEN 50539-11:2010 to install in<br />
Photovoltaic Systems<br />
• Pluggable class II surge protection<br />
• High discharge current of 40 kA (8/20 μs)<br />
• Optical function indicator red/green<br />
• Optional with remote signal contact<br />
• 180° rotatable insert<br />
Technical data<br />
Max. continious operating voltage UCPV mode +/-, -/PE, +/PE<br />
Requirements<br />
Nom. discharge current I (8/20 μs)<br />
n<br />
Max. discharge current I (8/20 μs)<br />
max<br />
Response time, ta, type<br />
Voltage protection level U mode (+/-, -/PE, +/PE)<br />
P<br />
Voltage protection level U @ I (per module)<br />
P n<br />
Housing type<br />
Optical function indicator<br />
Signalling contact<br />
Design<br />
Ambient temperature (operational)<br />
Storage temperature<br />
Connection as per IEC 947-7-1w<br />
Solid conductor<br />
Str<strong>and</strong>ed conductor<br />
Flexible conductor<br />
Approvals<br />
Dimensions<br />
Clamping range (rating- / min. / max.) mm2 Length x width x height mm<br />
Note<br />
Ordering data<br />
Version<br />
Accessories<br />
Plug-in spare arrester<br />
without telecomm. contact<br />
with telecomm. contact<br />
PU II 3/R 1,000 V DC PV<br />
11 12 14 + PE<br />
OK CHANGE OK CHANGE<br />
U U<br />
1,000 V DC<br />
UTE C 61-740-51 <strong>and</strong> the prEN 50539-11:2010<br />
15 kA<br />
40 kA<br />
< 25 ns<br />
≤ 4.2 kV<br />
≤ 2.65 kV<br />
Insta IP20<br />
green = OK; red = arrester faulty, replace<br />
250 V 1A 1CO at PU II 3 R<br />
3 TE; Installation housing<br />
-40 °C...70 °C<br />
-40 °C...70 °C<br />
Torque 3 Nm<br />
4...16 mm²<br />
4...25 mm²<br />
4...25 mm²<br />
UTE C 61-740-51; CE<br />
U<br />
-<br />
OK CHANGE<br />
without telecomm. contact with telecomm. contact<br />
25 / 4 / 25 25 / 4 / 25<br />
97 x 54 x 64 90 x 54 x 64<br />
Type Qty. Order No.<br />
PU II 3 1,000 V DC PV 1 1301680000<br />
PU II 3 R 1,000 V DC PV 1 1301690000<br />
PU II 0 PV +/- 1,000 V DC - 1254250000<br />