Tech Note: Memory-Card usage with <strong>SLS</strong>-<strong>500</strong> <strong>PLCs</strong><br />
Products:<br />
Revision: R100<br />
For all <strong>SLS</strong>-<strong>500</strong> Main Controllers and all <strong>SLS</strong>-<strong>500</strong>-Configurator versions<br />
Installation of the MemoryCard in<br />
<strong>SLS</strong>-<strong>500</strong> Main Controller<br />
The MemoryCard first has to be put into the provided<br />
card holder. Then it has to be inserted into the<br />
Controller as shown in the figure. If the MemoryCard<br />
has no contact the reading operation will give out a<br />
ZERO-value. If the MemoryCard is inserted correctly,<br />
everything will work similar to the description.<br />
HIQUEL ® GmbH Bairisch Kölldorf 266, A - 8344 Bad Gleichenberg<br />
Tel: +43-3159-3001, Fax: +43-3159-30014, e-mail: hiquel@hiquel.com http: www.hiquel.com<br />
Copying programs<br />
Having loaded a correct <strong>SLS</strong>-<strong>500</strong>-Configurator<br />
program to the MemoryCard, you can start the known<br />
PLC-manager with „Start->Dialog“. You will have the<br />
following options with the PLC-manager: First you can<br />
copy the current loaded <strong>SLS</strong>-<strong>500</strong>-Configurator<br />
program from the Main Controller to the MemoryCard<br />
by clicking the button „CC->MC“. You can also<br />
remove the MemoryCard from the Controller and<br />
insert it into another Controller, which will load the<br />
program automatically as soon as it gets voltage.