Sample for battery calculation<br />

GMDSS Reserve Battery Calculation ( 24 V DC )<br />

According to IMO Regulation COMSAR/Circ.16 4. March 1998<br />

A: with Emergency Generator ( SOLAS IV 13.2 )<br />

The GMDSS equipment shall be able to operate one (1) hour on reserve power<br />

With 50% of time in transmission mode and 50% in receiving mode.<br />

B: without Emergency Generator ( SOLAS IV 13.2 )<br />

The GMDSS equipment shall be able to operate six (6) hours on reserve power<br />

with 50% of time in transmission mode and 50 % of receiving mode.<br />

Equipment Type Transmitting Receiving Additional<br />

MF/HF STR 2000 R 15 A 4 A incl.DSC<br />

Inmarsat C STR 1500 CN 5 A 1,8 A incl.EGC<br />

VHF 1 with DSC VHF1000DSC 6,5 A 0,65 A incl.DSC<br />

VHF 2 with DSC VHF1000DSC 6,5 A 0,65 A incl.DSC<br />

AIS AIS - Unit 5,0 A 1,0 A<br />

Emergency Light 2,5 A<br />

Total 38 A 8,1 A 2.5 A<br />

Calculation:<br />

Case A:<br />

1h x ( 0.5 I TX + I RX + I Add ) x 1.4 = 41.44 Ah<br />

recommend battery capacity is 86 Ah<br />

Charger:<br />

I Charge x 0.1 I Batt/h = 8.6 A<br />

recommend charger is type 20 A<br />

Case B:<br />

6h x ( 0.5 I TX + I RX + I Add ) x 1.4 = 248.66 Ah<br />

The battery calculation should not be used for uninterruptible power supply (UPS)<br />

configuration