5.3.5 Internal Analogue Input Functions<br />

Ventura Remote PLC has:<br />

- 4 analogue inputs ai0, ai1, ai2 and ai3<br />

Software<br />

� To set up the resolution of every analogue input and<br />

to retrieve information about analogue input<br />

variables, choose "Resources, PLC Configuration,<br />

<strong>Kuhnke</strong> Ventura Remote IO CAN (or DP), Internal IO,<br />

AI 4".<br />

� Set the measuring range of every analogue input.<br />

� Enable or disable the filter (for all analogue inputs).<br />

� Analogue inputs read the analogue values of<br />

temperatures, fill levels, speeds, etc. The processor<br />

takes care of analogue-to-digital conversion. Digitized<br />

values can be further processed by the user program.<br />

Representation of analogue values:<br />

The resolution is 10 bit. Values are shown as two's<br />

complements in an integer-type variable.<br />

139