Output Module: Triggers the specified output module when the input is activated. Use the<br />

drop-down lists to select the output module<br />

<strong>and</strong> pin number to perform this function.<br />

Right Arrow button: Sets the time to delay the activation of the specified output module.<br />

Register Input Event: This option logs the alarm events into <strong>System</strong> Log. Each event<br />

is labeled<br />

with ID, time, device name (camera or I/O input), corresponding module of the device, <strong>and</strong> event<br />

for later retrieval. For details on <strong>System</strong> Log, see <strong>System</strong> Log in Chapter 1.<br />

Note: The Delay Time in Invoke to Send Alerts <strong>and</strong> Output Module allow you time<br />

to turn off the<br />

input<br />

device before the system triggers alerts or the output device. The Delay Time will not work if you<br />

stop monitoring or enable the function “Deactivate notification when selected pin ON" in I/O<br />

Application window (Figure 6-8).<br />

[Output X] Click the Arrow buttons to select an output.<br />

Apply to all Outputs<br />

Select Output<br />

Keep Last Toggle Status<br />

Figure 6-3<br />

Name: Specifies a name for the output device in the Name field.<br />

Force Output: Click to test signal to the selected device.<br />

Signal Type: There are six signal types available: N/O (Normal Open),<br />

N/O Toggle, N/O Pulse,<br />

N/C (Normal Closed), N/C Toggle, <strong>and</strong> N/C Pulse. Choose the<br />

one that mostly suits the device<br />

you’re using. For Toggle output type, the output continues to be triggered until a new input trigger<br />

ends the output. For Pulse output type, the output is triggered for the amount of time you specify<br />

in Sec field.<br />

Keep Last Toggle Status: See Keeping Last Toggle Status later in this chapter.<br />

Note: PTZ camera <strong>and</strong> I/O devices cannot be assigned to the same port at the same time.<br />