170 Industrial Hydraulics<br />

y<br />

Anwendungen<br />

yy<br />

Applications<br />

yyy<br />

Applications<br />

6<br />

Die <strong><strong>Position</strong>s</strong>reglerkarte übernimmt<br />

die „Punkt-zu-Punkt-Lageregelung“<br />

des Zylinders. Dazu vergleicht der<br />

Regler das Lageistwertsignal des<br />

Zylinders <strong>und</strong> die Lagesollwertsignale<br />

der Steuerung.<br />

Der <strong><strong>Position</strong>s</strong>regler bildet daraus das<br />

Sollwertsignal für den Ventilverstärker<br />

zur Ansteuerung des Regelventils für<br />

die Zylinderbewegung.<br />

Zur <strong><strong>Position</strong>s</strong>erfassung des Zylinders<br />

wird das integrierte Wegmeßsystem<br />

(Potentiometer) an b2/b4 angeschlossen.<br />

Mit der <strong>Position</strong>ierlogik sind 3 <strong>Position</strong>en<br />

anfahrbar (P3 Gr<strong>und</strong>stellung, P1<br />

obere Reversierstellung, P2 untere<br />

Reversierstellung). Die Sollwerte für<br />

diese <strong>Position</strong>en sind durch die<br />

externe Steuerung vorgebbar oder<br />

intern über Potentiometer einstellbar.<br />

Die interne Sollwertvorgabe ist besonders<br />

für relativ weit tolerierte Sollwerte<br />

<strong>und</strong> in ihrem Wert konstante <strong>Position</strong>en<br />

geeignet.<br />

Für eng tolerierte Sollwerte, welche<br />

in ihrem Wert konstant sind, kann<br />

z. B. das externe Potentiometer<br />

« B 830 303 560 eingesetzt werden.<br />

Für sich ändernde Sollwerte muß der<br />

externe Modus geschaltet werden.<br />

Der <strong>Position</strong> P3 ist dabei der kleinste<br />

Sollwert zugeordnet. Durch <strong><strong>Position</strong>s</strong>befehle<br />

von der übergeordneten<br />

Maschinensteuerung werden die <strong><strong>Position</strong>s</strong>sollwerte<br />

angefahren. Liegen<br />

<strong><strong>Position</strong>s</strong>befehle für P1 <strong>und</strong> P2 gleichzeitig<br />

an, so erfolgt ein Oszillieren<br />

zwischen beiden Punkten. Ein <strong>Position</strong>ierbefehl<br />

P3 unterbricht in jedem Fall<br />

eine andere Bewegung <strong>und</strong> fährt den<br />

Zylinder in die P3-<strong>Position</strong>.<br />

Die Bewegungsgeschwindigkeit des<br />

Zylinders wird über einen Sollwert vorgegeben,<br />

der ebenfalls extern oder<br />

intern generierbar ist. Die Ist-<strong>Position</strong><br />

des Zylinders ist als Monitorsignal abgreifbar<br />

(z4). Für besondere Einsatzfälle<br />

ist es möglich, das Sollwertsignal<br />

über einen Rampenbildner zu führen<br />

(S11, S10). Durch LEDs wird über die<br />

<strong>Position</strong> des Zylinders, über evtl.<br />

Kabelbruch des Wegaufnehmers sowie<br />

über die vorhandene Versorgungsspannung<br />

informiert.<br />

The position controller card assumes<br />

“point-to-point position control” of the<br />

cylinder. For this, the position controller<br />

compares the feedback position<br />

signal of the cylinder and the setpoint<br />

position signals of the control. From<br />

this, the position controller then forms<br />

the setpoint signal for the valve amplifier,<br />

to trigger the servo solenoid valve<br />

and thus move the cylinder.<br />

To record the position of the cylinder,<br />

the integrated position measuring<br />

system (potentiometer) is connected<br />

to b2/b4.<br />

The positioning logic allows for the<br />

selection of 3 positions (P3, basic<br />

position; P1, upper reversing position;<br />

P2 lower reversing position). The setpoint<br />

values for these positions can be<br />

entered at the external control level or<br />

set internally via potentiometer.<br />

The internal entry of setpoints is particularly<br />

suitable for setpoints with a<br />

relatively wide tolerance and positions<br />

with a constant value.<br />

For setpoints with a narrow tolerance<br />

which have a constant value,<br />

the external potentiometer<br />

« B 830 303 560 may be employed,<br />

for example.<br />

For changing setpoints, the system<br />

must be switched to external mode.<br />

The smallest setpoint is assigned to<br />

position P3. <strong>Position</strong> commands from<br />

the priority-level machine control<br />

initiate the move to the position setpoints.<br />

When position commands for<br />

P1 and P2 are present simultaneously,<br />

the system oscillates between the two<br />

points. The P3 position command<br />

always interrupts any other motion to<br />

return the cylinder to position P3.<br />

A setpoint value specifies the velocity<br />

of the cylinder. This value can be<br />

generated either internally or externally.<br />

The actual feedback position of the<br />

cylinder is available in the form of a<br />

monitor signal (z4). The setpoint signal<br />

can be relayed through a ramp generator<br />

to deal with particular applications<br />

(S11, S10). LEDs provide information<br />

on the position of the cylinder,<br />

possible open circuit in the position<br />

transducer circuit, and actual supply<br />

voltage.<br />

La carte de régulation de position<br />

assure la «régulation de position point<br />

par point» du vérin. Pour ce faire, le<br />

régulateur compare le signal de retour<br />

de position du vérin et les signaux de<br />

consigne de position de la commande.<br />

Le régulateur de position forme à<br />

partir de là le signal de consigne pour<br />

l’amplificateur de valve servant à piloter<br />

le servo-distributeur pour le<br />

déplacement du vérin.<br />

Pour détecter la position du vérin, le<br />

système de mesure de position intégré<br />

(potentiomètre) est raccordé aux<br />

bornes b2/b4.<br />

La logique de positionnement permet<br />

d’appeler 3 positions (P3 position de<br />

base, P1 position réversible<br />

supérieure, P2 position réversible<br />

inférieure). Les signaux de consigne<br />

pour ces positions peuvent être délivrés<br />

par la commande numérique<br />

externe ou préréglés en interne par le<br />

biais de potentiomètres.<br />

La présélection des signaux de consigne<br />

en interne convient particulièrement<br />

bien pour les signaux de consigne<br />

à tolérance relativement importante<br />

et pour les positions constantes<br />

en valeur.<br />

Pour les signaux de consigne à<br />

tolérance étroite qui sont constants<br />

en valeur, il est possible d’utiliser<br />

p. ex. le potentiomètre externe<br />

« B 830 303 560.<br />

Pour les signaux de consigne variables,<br />

il faut passer au mode externe.<br />

La position P3 se voit attribuer le<br />

signal de consigne le plus faible. Les<br />

ordres de positionnement venant de la<br />

commande numérique permettent de<br />

sélectionner les signaux de consigne<br />

de position. Si des ordres de positionnement<br />

pour P1 et P2 sont émis<br />

simultanément, il s’ensuit une oscillation<br />

entre les 2 points. Un ordre de<br />

positionnement P3 est prioritaire et<br />

remet immédiatement le vérin en<br />

position P3. La vitesse de déplacement<br />

du vérin est limitée par un signal<br />

de consigne, qui peut être généré en<br />

interne ou par une source externe. La<br />

position réelle du vérin est disponible<br />

sous forme de signal du moniteur (z4).<br />

Pour certains cas d’applications spéciaux,<br />

il est possible de modifier le<br />

signal de consigne par un générateur<br />

de rampes (S11, S10 ).