170 Industrial Hydraulics<br />
y<br />
Anwendungen<br />
yy<br />
Applications<br />
yyy<br />
Applications<br />
6<br />
Die <strong><strong>Position</strong>s</strong>reglerkarte übernimmt<br />
die „Punkt-zu-Punkt-Lageregelung“<br />
des Zylinders. Dazu vergleicht der<br />
Regler das Lageistwertsignal des<br />
Zylinders <strong>und</strong> die Lagesollwertsignale<br />
der Steuerung.<br />
Der <strong><strong>Position</strong>s</strong>regler bildet daraus das<br />
Sollwertsignal für den Ventilverstärker<br />
zur Ansteuerung des Regelventils für<br />
die Zylinderbewegung.<br />
Zur <strong><strong>Position</strong>s</strong>erfassung des Zylinders<br />
wird das integrierte Wegmeßsystem<br />
(Potentiometer) an b2/b4 angeschlossen.<br />
Mit der <strong>Position</strong>ierlogik sind 3 <strong>Position</strong>en<br />
anfahrbar (P3 Gr<strong>und</strong>stellung, P1<br />
obere Reversierstellung, P2 untere<br />
Reversierstellung). Die Sollwerte für<br />
diese <strong>Position</strong>en sind durch die<br />
externe Steuerung vorgebbar oder<br />
intern über Potentiometer einstellbar.<br />
Die interne Sollwertvorgabe ist besonders<br />
für relativ weit tolerierte Sollwerte<br />
<strong>und</strong> in ihrem Wert konstante <strong>Position</strong>en<br />
geeignet.<br />
Für eng tolerierte Sollwerte, welche<br />
in ihrem Wert konstant sind, kann<br />
z. B. das externe Potentiometer<br />
« B 830 303 560 eingesetzt werden.<br />
Für sich ändernde Sollwerte muß der<br />
externe Modus geschaltet werden.<br />
Der <strong>Position</strong> P3 ist dabei der kleinste<br />
Sollwert zugeordnet. Durch <strong><strong>Position</strong>s</strong>befehle<br />
von der übergeordneten<br />
Maschinensteuerung werden die <strong><strong>Position</strong>s</strong>sollwerte<br />
angefahren. Liegen<br />
<strong><strong>Position</strong>s</strong>befehle für P1 <strong>und</strong> P2 gleichzeitig<br />
an, so erfolgt ein Oszillieren<br />
zwischen beiden Punkten. Ein <strong>Position</strong>ierbefehl<br />
P3 unterbricht in jedem Fall<br />
eine andere Bewegung <strong>und</strong> fährt den<br />
Zylinder in die P3-<strong>Position</strong>.<br />
Die Bewegungsgeschwindigkeit des<br />
Zylinders wird über einen Sollwert vorgegeben,<br />
der ebenfalls extern oder<br />
intern generierbar ist. Die Ist-<strong>Position</strong><br />
des Zylinders ist als Monitorsignal abgreifbar<br />
(z4). Für besondere Einsatzfälle<br />
ist es möglich, das Sollwertsignal<br />
über einen Rampenbildner zu führen<br />
(S11, S10). Durch LEDs wird über die<br />
<strong>Position</strong> des Zylinders, über evtl.<br />
Kabelbruch des Wegaufnehmers sowie<br />
über die vorhandene Versorgungsspannung<br />
informiert.<br />
The position controller card assumes<br />
“point-to-point position control” of the<br />
cylinder. For this, the position controller<br />
compares the feedback position<br />
signal of the cylinder and the setpoint<br />
position signals of the control. From<br />
this, the position controller then forms<br />
the setpoint signal for the valve amplifier,<br />
to trigger the servo solenoid valve<br />
and thus move the cylinder.<br />
To record the position of the cylinder,<br />
the integrated position measuring<br />
system (potentiometer) is connected<br />
to b2/b4.<br />
The positioning logic allows for the<br />
selection of 3 positions (P3, basic<br />
position; P1, upper reversing position;<br />
P2 lower reversing position). The setpoint<br />
values for these positions can be<br />
entered at the external control level or<br />
set internally via potentiometer.<br />
The internal entry of setpoints is particularly<br />
suitable for setpoints with a<br />
relatively wide tolerance and positions<br />
with a constant value.<br />
For setpoints with a narrow tolerance<br />
which have a constant value,<br />
the external potentiometer<br />
« B 830 303 560 may be employed,<br />
for example.<br />
For changing setpoints, the system<br />
must be switched to external mode.<br />
The smallest setpoint is assigned to<br />
position P3. <strong>Position</strong> commands from<br />
the priority-level machine control<br />
initiate the move to the position setpoints.<br />
When position commands for<br />
P1 and P2 are present simultaneously,<br />
the system oscillates between the two<br />
points. The P3 position command<br />
always interrupts any other motion to<br />
return the cylinder to position P3.<br />
A setpoint value specifies the velocity<br />
of the cylinder. This value can be<br />
generated either internally or externally.<br />
The actual feedback position of the<br />
cylinder is available in the form of a<br />
monitor signal (z4). The setpoint signal<br />
can be relayed through a ramp generator<br />
to deal with particular applications<br />
(S11, S10). LEDs provide information<br />
on the position of the cylinder,<br />
possible open circuit in the position<br />
transducer circuit, and actual supply<br />
voltage.<br />
La carte de régulation de position<br />
assure la «régulation de position point<br />
par point» du vérin. Pour ce faire, le<br />
régulateur compare le signal de retour<br />
de position du vérin et les signaux de<br />
consigne de position de la commande.<br />
Le régulateur de position forme à<br />
partir de là le signal de consigne pour<br />
l’amplificateur de valve servant à piloter<br />
le servo-distributeur pour le<br />
déplacement du vérin.<br />
Pour détecter la position du vérin, le<br />
système de mesure de position intégré<br />
(potentiomètre) est raccordé aux<br />
bornes b2/b4.<br />
La logique de positionnement permet<br />
d’appeler 3 positions (P3 position de<br />
base, P1 position réversible<br />
supérieure, P2 position réversible<br />
inférieure). Les signaux de consigne<br />
pour ces positions peuvent être délivrés<br />
par la commande numérique<br />
externe ou préréglés en interne par le<br />
biais de potentiomètres.<br />
La présélection des signaux de consigne<br />
en interne convient particulièrement<br />
bien pour les signaux de consigne<br />
à tolérance relativement importante<br />
et pour les positions constantes<br />
en valeur.<br />
Pour les signaux de consigne à<br />
tolérance étroite qui sont constants<br />
en valeur, il est possible d’utiliser<br />
p. ex. le potentiomètre externe<br />
« B 830 303 560.<br />
Pour les signaux de consigne variables,<br />
il faut passer au mode externe.<br />
La position P3 se voit attribuer le<br />
signal de consigne le plus faible. Les<br />
ordres de positionnement venant de la<br />
commande numérique permettent de<br />
sélectionner les signaux de consigne<br />
de position. Si des ordres de positionnement<br />
pour P1 et P2 sont émis<br />
simultanément, il s’ensuit une oscillation<br />
entre les 2 points. Un ordre de<br />
positionnement P3 est prioritaire et<br />
remet immédiatement le vérin en<br />
position P3. La vitesse de déplacement<br />
du vérin est limitée par un signal<br />
de consigne, qui peut être généré en<br />
interne ou par une source externe. La<br />
position réelle du vérin est disponible<br />
sous forme de signal du moniteur (z4).<br />
Pour certains cas d’applications spéciaux,<br />
il est possible de modifier le<br />
signal de consigne par un générateur<br />
de rampes (S11, S10 ).