6 Positions- und Geschwindigkeitsregler Position ... - Bosch Rexroth
6 Positions- und Geschwindigkeitsregler Position ... - Bosch Rexroth
6 Positions- und Geschwindigkeitsregler Position ... - Bosch Rexroth
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
174 Industrial Hydraulics<br />
yy<br />
Specifications<br />
PCB Format<br />
Plug connection Plug to DIN 41 612-F32<br />
Ambient temperature<br />
(100 x 160 x approx. 35) mm (W x L x H), Europe format with front plate<br />
(7 modular spacings)<br />
0 °C ... +70 °C,<br />
storage temperature min. –20 °C;<br />
max. +70 °C<br />
<strong>Position</strong> transducer<br />
DC position transducer at b4/b2,<br />
U sig = 0 ... +10 V<br />
<strong>Position</strong> setpoints 0 ... 10 V = (0 V cylinder position P3)<br />
<strong>Position</strong> commands<br />
6 ... 40 V = (nom. 10 V=)<br />
Velocity setpoint 0 ... 10 V =<br />
Setpoint ramp t min = 510 ms<br />
t max = 500 ms<br />
Special features<br />
LED displays<br />
Adjustment options<br />
All setpoints can be assigned internally or externally<br />
Test connections for all major signals<br />
Open circuit recognition for position transducer<br />
Setpoint ramp<br />
<strong>Position</strong> 1–3 reached/not reached<br />
Open circuit<br />
U B ON<br />
Zero-point of position transducer<br />
<strong>Position</strong> transducer amplifier<br />
Velocity<br />
<strong>Position</strong> setpoints, internal<br />
Attention:<br />
Power zero b12 and control zero b14 must be bridged.<br />
For distance from power supply unit < 1 m, direct to DIN-plug.<br />
For distance > 1 m, route control zero separately to gro<strong>und</strong>.<br />
6<br />
Attention:<br />
The supply voltage U B of the<br />
system’s valve amplifier card<br />
may not exceed the following<br />
values:<br />
24 V DC nominal<br />
battery voltage 21 ... 34 V<br />
rectified AC voltage<br />
U rms = 21 ... 25 V